Permit Review Detail
Review Status: Completed
Review Details: REVISION - - 2ND
Permit Number - T14CM08365
Review Name: REVISION - - 2ND
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/14/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Comment not addressed. The calculation of the required number of plumbing fixtures is still incorrect: 3 water closets and 2 lavatories are still required for each sex. The occupiable area under the canopy has not been addressed. [Second comment: Clarify how the new occupiable area for the canopy area has been determined. If you have ever waited for service under one of those canopies, you know it is an occupiable area (albeit not necessarily 100 square feet per person). Aside from the number of occupants, the fixture calculations are incorrect. Assuming 110 total people inn the B occupancy (55 of each sex), three water closets and 2 lavatories are required for each sex.] [Initial comment: The number of required fixtures shown in Table 2902.1, IBC 2012 is based upon the minimum fixtures required for each person or fraction of the number of persons. Since fractional fixtures cannot be installed, fractional numbers for fixtures shall also be rounded up to the next whole number. Increase the number of required lavatories to 3 lavatories in each restroom. Reference: footnote (a), Table 2902.1, IBC 2012.] 2. Comment not addressed. [Second comment: See the new comment above.] [Initial comment: No more than 50% of the required water closets in a restroom may be substituted with urinals. Reference: Section 419.2, IPC 2012.] |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/24/2015 | AROMERO4 | APPROVAL SHELF | Completed |
| 07/24/2015 | AROMERO4 | OUT TO CUSTOMER | Completed |