Permit Review Detail
Review Status: Completed
Review Details: REVISION - - 2ND
Permit Number - T14CM08365
Review Name: REVISION - - 2ND
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/18/2015 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | |
| 06/25/2015 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 07/13/2015 | CLAYTON TREVILLYAN | BUILDING-COMMERCIAL | REVIEW | Reqs Change | BUILDING PLAN REVIEW COMMENTS Date: 7-13-15 Activity: T14CM08365 Address: 850 W. Auto Mall Dr Applicant: Metro TED This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Building Code and local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions and concerns before permit approval. Sheet T1 1. Please include sheet A4.3 on sheet index. 2. Square footage areas indicated on occupant load calculations are not consistent with the proposed addition area. Please provide an accurate occupant load calculation that includes the proposed service area and adjust the occupant loads accordingly, 1004, 2902. If you have any questions please contact: Clayton Trevillyan, CBO 520.837.4913 Clayton.Trevillyan@tucsonaz.gov |
| 07/14/2015 | AROMERO4 | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Clarify how the new occupiable area for the canopy area has been determined. If you have ever waited for service under one of those canopies, you know it is an occupiable area (albeit not necessarily 100 square feet per person). Aside from the number of occupants, the fixture calculations are incorrect. Assuming 110 total people inn the B occupancy (55 of each sex), three water closets and 2 lavatories are required for each sex. [Initial comment: The number of required fixtures shown in Table 2902.1, IBC 2012 is based upon the minimum fixtures required for each person or fraction of the number of persons. Since fractional fixtures cannot be installed, fractional numbers for fixtures shall also be rounded up to the next whole number. Increase the number of required lavatories to 3 lavatories in each restroom. Reference: footnote (a), Table 2902.1, IBC 2012.] 2. See the new comment above. [Initial comment: No more than 50% of the required water closets in a restroom may be substituted with urinals. Reference: Section 419.2, IPC 2012.] |
| 07/14/2015 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/14/2015 | AROMERO4 | APPROVAL SHELF | Completed |
| 07/14/2015 | AROMERO4 | OUT TO CUSTOMER | Completed |