06/09/2015 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change Provide an updated Envelope Compliance Certificate to demonstrate energy code compliance for the alterations to the building envelope. Reference: Sections C101.4.3, C101.5, and C103.2, International Energy Conservation Code 2012.
06/09/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. The number of required fixtures shown in Table 2902.1, IBC 2012 is based upon the minimum fixtures required for each person or fraction of the number of persons. Since fractional fixtures cannot be installed, fractional numbers for fixtures shall also be rounded up to the next whole number. Increase the number of required lavatories to 3 lavatories in each restroom. Reference: footnote (a), Table 2902.1, IBC 2012.
2. No more than 50% of the required water closets in a restroom may be substituted with urinals. Reference: Section 419.2, IPC 2012.
06/10/2015 MARTIN BROWN FIRE REVIEW Approved
06/16/2015 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
06/18/2015 AROMERO4 BUILDING-COMMERCIAL REVIEW Needs Review