Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T14CM08020
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/29/2014 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 12-30-14 Activity: T14CM08020 Address: 2810 N Barrio Mesquite Applicant: Chuck Meyer This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. SITE PLAN: 1. Indicate on the site plan the extent of the building limits or remove pages for optional layout from building plan. INCLUSIVE HOME DESIGN: 2. Remove references to Unincorporated Pima County. 3. Specify all switches, receptacles, and controls within 15 to 48 inches of the floor (To include thermostat controls), 1003.9. FOUNDATION PLAN: 4. Provide tendon spacing in long direction consistent with post tension calculations. STRUCTURAL / FRAMING PLAN: 5. Clarify question marks found on sheet S3. SECTIONS - DETAILS: 6. Provide updated stamps from Arizona Registrants for unvented roof design or remove details and specify compliance with the prescriptive measures found at R806.5. 7. Clarify section reference 17-D1 as specified on sheet A4. 8. Clarify wall anchorage on section details. Detail 1-D2 is inconsistent with other wall anchorage details. PLUMBING PLAN: 9. Cleanouts are required at the kitchen sink area, State amendment. 10. Specify water conservation requirements consistent with the adopted standards: Water closets = 1.6 gallons per flush, Sinks = 2.2 gpm, Showerheads = 2.5 gpm, P2903.2. MECHANICAL PLAN: 11. Justify Manual J values provided. One area calls for 18 occupants while other areas call for 13 or 5 occupants and the insulation values do not coincide with building plan. OUTDOOR LIGHTING CODE 12. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Model plans should specify a minimum lot size for the proposed exterior lighting. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Clayton.Trevillyan@tucsonaz.gov Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/09/2015 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |