Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T14CM07887
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/12/2015 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 1-8-14 Activity: T14CM07887 Address: 819 W. Wyoming Applicant: Danny Quihuis GENERAL REQUIREMENTS: 1. The seal of professional registration is expired. Please provide an updated seal. PREVIOUS COMMENTS: 2. Provide a complete set of notes on the plan to meet the Inclusive Home Design Ordinance 10463. Note: The minimum door widths have been specified in the IHD notes but the door call outs on the floor plan do not comply. Correct the door widths along the accessible route accordingly. 3. Provide a mechanical equipment specification list, M1302.1. Note: Neither of the mechanical units specified can be located on the manufacturer's web sites http://www.comfort-aire.com/room-air-conditioners http://www.westinghousehvac.com/SearchResults.asp?Search=wav157 4. Provide Manual J/S calculations for the forced air units in accordance with M1401.3, M1601.1. Note: ResCheck analysis is not equivalent to the heating and cooling load software required by ACCA. Manual J software determines the heating and cooling demand based on the building design and Manual S software determines a mechanical system's ability to meet the demand under the specified climatic conditions. 5. Show receptacle outlets at each kitchen counter space wider than 12" so that no point along the wall line is more than 24" from a receptacle outlet, E3901.4.1. Note: Counter spaces that measure 12 inches or more must have a receptacle as specified above. Provide a GFCI protected receptacle between the cooking range and the refrigerator or indicate the counter dimension less than 12". 6. Show receptacle outlets at wall spaces 2' or more so that no point along the wall (excluding door openings) is more than 6' from a receptacle outlet, E3901.2. Note: All wall spaces greater than 24 inches must have a receptacle as specified above. Include a receptacle on the bedroom wall between the door and the closet as well as on the shared wall between the dining room and the bathroom. 7. On June 17, 2008, Mayor and Council unanimously voted to require all new residences to be solar ready for electric (PV). B. Indicate the best roof space available for accommodating future PV solar collector panels with capacity for collector dead loading (typically 4 lbs/SF). C. A minimum 3,800 volt-ampere PV electrical load entry on the Service Load Calculation (show as a continuous load of 15.8 A). Note: The proposed roof location of the future PV system has not been indicated. Specify the location and ensure the roof is capable of supporting the additional structural load. The electrical load must be calculated as continuous so the 40% reduction does not apply. Show this load with the heating and cooling entry calculated at 100%. 8. Specify the insulation material that will provide a minimum of R-38 in the proposed 9.25" cavity. Note: The ResCheck analysis indicates a roof insulation value of R30 and the plan indicates R38, clarify. The plan now indicates batt insulation and an asphalt shingle roof system. This combination would require a continuous layer of rigid R5 insulation either directly above or directly below the roof sheathing, R806.5. 9. Specify how the hot water lines will be insulated between the adjoining buildings, N1103.4.2. Note: Indicate the proposed insulation material listed for direct burial and the R-value associated. A review meeting may be scheduled with the plan reviewer specified below at your convenience if any of these items are unclear. A meeting must be scheduled with the designer and the property owner if these items are not addressed on the next submittal. Clayton Trevillyan 520.837.4913 Clayton.Trevillyan@tucsonaz.gov Residential Plan Review |