Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T14CM07887
Parcel: 137053320

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T14CM07887
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/08/2015 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Reqs Change PLAN REVIEW COMMENTS
Date: 1-8-14
Activity: T14CM07887
Address: 819 W. Wyoming
Applicant: Danny Quihuis

This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Remove plan pages that do not pertain to this project.

INCLUSIVE HOME DESIGN:
2. Provide a complete set of notes on the plan to meet the Inclusive Home Design Ordinance 10463.

STRUCTURAL / FRAMING PLAN:
3. Specify sheathing thickness on sheet A1.1.
4. Specify anchor bolt spacing on sheet A1.1.
5. Provide braced wall panels within 10 feet of the ends of braced wall lines, Table R602.10.3(1).
6. Provide minimum 4' wide braced wall panels or include specifications for alternate braced wall panels in accordance with R602.10.6.1.
7. Provide wall bracing on north and east facing wall lines.
8. Justify the ability of the proposed 2x12 to support the porch roof assembly.

PLUMBING PLAN:
9. All construction drawings submitted after June 1, 2010 for one- or two-family dwellings must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. Provide gray water segregation for at least one (1) bathing fixture or clothes washing machine for all single story buildings when the available distribution area exceeds 200 square feet (Gravity discharge is required when feasible).

MECHANICAL PLAN:
10. Provide a mechanical equipment specification list, M1302.1.
11. Provide Manual J/S calculations for the forced air unit in accordance with M1401.3, M1601.1.

ELECTRICAL PLAN:
12. Show receptacle outlets at each kitchen counter space wider than 12" so that no point along the wall line is more than 24" from a receptacle outlet, E3901.4.1.
13. Show receptacle outlets at wall spaces 2' or more so that no point along the wall (excluding door openings) is more than 6' from a receptacle outlet, E3901.2.
14. Bathroom receptacles may not share a circuit with outlets located outside the bathroom area, E3703.4, E3901.6.
15. Automatic clothes washing machines may not share a circuit with lighting outlets, E3703.3, 3901.8.
16. Include a 1500 watt load entry for each appliance circuit on the electrical load calculations, E3602.2.
17. On June 17, 2008, Mayor and Council unanimously voted to require all new residences to be solar ready for electric (PV). Starting July 1, 2009, all new single family homes or duplexes must include in the plans either a photovoltaic system or preparation for later installation of a PV system in order to receive a permit. Photovoltaic Preparation must include all of the following: A. Reserve a 4 square foot area for equipment (meter, disconnect & inverter) adjacent to the electrical service panel or near the proposed collector panel space. B. Indicate the best roof space available for accommodating future PV solar collector panels with capacity for collector dead loading (typically 4 lbs/SF). C. A minimum 3,800 volt-ampere PV electrical load entry on the Service Load Calculation (show as a continuous load of 15.8 A). D. An Electrical Panel Schedule with a 240 volt circuit breaker space (two slots) labeled "reserved for Photo Voltaic".

INTERNATIONAL ENERGY CONSERVATION CODE:
18. Specify the insulation material that will provide a minimum of R-38 in the proposed 9.25" cavity.
19. Specify how the hot water lines will be insulated between the adjoining buildings, N1103.4.2.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Clayton.Trevillyan@tucsonaz.gov
Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
02/11/2015 CPIERCE1 REJECT SHELF Completed