Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T14CM07531
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/27/2015 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 02/02/2015 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 02/02/2015 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 02/02/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide the calculations used to determine the water demand for the building; using Tables E103.3 (2) and E103.3 (3), IPC 2012 for public fixtures in a predominately flush-valve system, the demand is approximately 80 GPM, not 40 GPM. Reference: Section 604.1, IPC 2012. [Initial comment: Verify that the water velocity in the proposed 2" water service pipe will not exceed the maximum velocity recommended by the manufacturer (i.e. 8 FPS). Reference: Section 303.2, IPC 2012.] 2. Specify ASSE 1070-listed mixing valves for the lavatories in the restrooms. [Initial comment: Provide tempered water for the lavatories and public hand-washing sinks in restrooms using approved devices conforming to ASSE 1070. Reference: Sections 416.5 and 607.1.2, IPC 2012.] 3. Coffee makers and other beverage dispensers require the use of backflow preventers listed to ASSE 1022; the proposed dual check valve (the LF7RU-U2 is not a vacuum breaker) is listed to ASSE 1024. Reference: Section 608.16.10, IPC 2012. [Initial comment: The Watts model Cu7 double check valve is an obsolete product and does not have an ASSE listing. Provide a backflow protection device that is listed for the intended application. Reference: Sections 608.1 and 608.16.10, IPC 2012.] 4. The next upstream manhole is shown on sheet C701 and appears to have a rim elevation of about 3019'. Verify the rim elevation with the civil engineers and determine the need for a backwater valve per Section 715.1, IPC 2012, as amended by the City of Tucson. [Initial comment: Provide the rim elevation of the next upstream sanitary manhole and the first floor elevation. Determine the need for a backwater valve per Section 715.1, IPC 2012, as amended by the City of Tucson.] |
| 02/06/2015 | KEN VAN KARSEN | ELECTRICAL-COMMERCIAL | REVIEW | Completed | |
| 02/24/2015 | LOREN MAKUS | ENGINEERING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/25/2015 | SHANAE POWELL | OUT TO CUSTOMER | Completed |
| 02/25/2015 | CPIERCE1 | REJECT SHELF | Completed |