Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T14CM07491
Parcel: 112033530

Address:
2524 E LIND RD

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T14CM07491
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/04/2014 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Reqs Change PLAN REVIEW COMMENTS
Date: 12-5-14
Activity: T14CM07491
Address: 2524 E Lind
Applicant: Richard Studwell

This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

INCLUSIVE HOME DESIGN:
1. Provide an accessible route from the public way extending throughout the entire first floor (except for exempt areas as defined in section 1003.3), 1003.2. The elevation drawing or the site plan must show a ramped sidewalk if a paved driveway is not the accessible route.

FLOOR PLAN:
2. Doors between a garage and a residence shall be self-closing, R302.5.1.
3. The walls and soffit of the enclosed space under stairs shall be protected on the enclosed side with ½" gypsum board, R302.7.

STRUCTURAL / FRAMING PLAN:
4. LPI floor joists are undersized for the proposed span.
5. Specify the size of the beam over the garage door.
6. Indicate the slope of the roof deck and location of drainage.

ELEVATIONS:
7. Specify two-layer underlayment for low-slope shingle roofs (2:12 to 4:12), R905.2.7.
8. Include roof mounted HVAC system on elevation drawings.

SECTIONS - DETAILS:
9. Specify how the ledger will be attached to the building in details 10 and 13 on page 7.
10. Provide draft stops between roof and wall cavities on details 10 and 12 on page 7.
11. Indicate roof covering material for roof deck.

PLUMBING PLAN:
12. Specify the diameter of the proposed water supply line from the meter to the service entrance, P2903.7.
13. All construction drawings submitted after June 1, 2010 for one- or two-family dwellings must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. Provide gray water segregation for at least one (1) bathing fixture or clothes washing machine for all single story buildings and all bathing fixtures and clothes washers on stories above grade level when the available distribution area exceeds 200 square feet. Gravity discharge is required when feasible including all fixtures on stories above grade level. Gray water stacks from upper floors must pass through an exterior-wall for future gravity distribution that includes a stub out with an aliened 2" vertical drop colored purple to a cleanout cap 2' above grade.
14. All construction drawings submitted after March 1, 2009 for one- or two-family dwellings require a solar water heating system, or future installation preparation with one of the following provisions: control and ¾"water piping; 3" metallic sleeve; or an accessible attic over the water heater, Ordinance 10549.
15. Show the size and location of cleanouts at the base of vertical waste or soil stacks, P3005.2.

MECHANICAL PLAN:
16. Provide Manual S calculations for the forced air unit in accordance with M1401.3, M1601.1.
17. Air inlets (including operable windows) shall be located a minimum of 10' from mechanical exhaust unless the outlet is 3 feet above the air inlet, M1602.2.1.
18. Specify mechanical supply and return duct sizes consistent with the Manual D calculations.
19. Provide consistent information between the building plans and the Manual J calculations for the proposed insulation values.
20. Return air may not be taken from kitchens, M1602.2.

ELECTRICAL PLAN:
21. Peninsula counter tops with a long dimension of 24" and a short dimension of 12" or greater shall have at least one receptacle, E3901.4.2/3.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Clayton.Trevillyan@tucsonaz.gov
Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
12/08/2014 KROBLES1 APPROVAL SHELF Completed
12/08/2014 KROBLES1 OUT TO CUSTOMER Completed
12/08/2014 CPIERCE1 REJECT SHELF Completed