11/14/2014 MICHAEL ST. PAUL ZONING REVIEW Reqs Change P&DS TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T14CM07332
237 South Avenida Del Palo Fiero
New SFR in Mercado District (PAD 10)


TRANSMITTAL: November 14, 2014


COMMENTS: the following comments are for a single-family residence (SFR).


This site is located in the Menlo Park Mercado District Lot 53 (PAD 10).

The approval stamp for the Mercado District Design Review Committee must be "affixed to each sheet" (p.43 PAD 10).
11/17/2014 MICHAEL ST. PAUL NPPO REVIEW Needs Review
12/02/2014 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Reqs Change PLAN REVIEW COMMENTS
Date: 12-2-14
Activity: T14CM07332
Address: 237 S. Avenida del Palo Fiero
Applicant: Tom Kirschner

This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Engineer of record must seal layout pages S1, S2.

INCLUSIVE HOME DESIGN:
2. Specify all switches, receptacles, and controls within 15 to 48 inches of the floor (To include thermostat controls), 1003.9.

STRUCTURAL / FRAMING PLAN:
3. Provide post tension spacing consistent with the structural calculations submitted.
4. Provide bond beams in masonry screen wall with reinforcement per structural calculations.
5. Provide reinforcement in screen wall footing consistent with structural calculations.
6. Provide continuous footings under all interior bearing walls per structural calculations.
7. Provide ledger schedule as referenced on section detail 9-S6.1.
8. Provide minimum 3" nominal ledgers when directly attached to masonry wall for detail 4-S6.1.
9. Justify roof beam size for proposed roof load including HVAC equipment.

PLUMBING PLAN:
10. Show the size and location of waste cleanouts at kitchen sink and at the base of vertical waste stacks, P3005.2.

ELECTRICAL PLAN:
11. Show receptacle outlets at each kitchen counter space wider than 12" so that no point along the wall line is more than 24" from a receptacle outlet, E3901.4.1. Ref. between sink and range.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Clayton.Trevillyan@tucsonaz.gov
Residential Plan Review