Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T14CM07013
Parcel: 137055230

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T14CM07013
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/12/2014 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved
12/24/2014 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. RTU-5 does not serve just the proposed Starbucks area. Revise the ventilation calculations using the occupant densities described in Table 403.3, IMC 2012 for the areas served by RTU-5. [Initial comment: Provide calculations demonstrating adequate ventilation using the current code. Reference: Section 403.2, IMC 2012.]
2. Microwave and convection ovens are defined as light-duty cooking appliances; Provide the general room exhaust required in Section 507.2.2, IMC 2012. [Initial comment: Provide general room exhaust for any cooking appliance that does not require the installation of a Type II hood. The minimum exhaust rate shall be 0.70 CFM per square foot, using a minimum area of 100 square feet for each individual appliance. Reference: Section 507.2.2, IMC 2012.]
12/24/2014 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Work sinks SB-0908 and SB-0901 are noted as requiring indirect wastes in the Starbucks Coffee Equipment Schedule. Work sink SB0908 is shown as having a direct connection in the coffee area waste and vent riser diagram but only a floor sink is shown in the area where work sink SB-0901 is located. Explain why work sink SB-0901 should not be directly-connected to grease waste instead of sanitary waste. [Initial comment: Provide a direct connection to the building drainage system for all plumbing fixtures except as allowed by Chapter 8, IPC 2012. Reference: Section 301.3, IPC 2012.]
2. Yves Khawam is the Chief Building Official of Pima County but he has no authority in the City of Tucson. If you wish to discuss this with the Building Official for the City of Tucson, contact Chris Kiel at (520) 837-4937. [Initial comment: A dishwasher may not discharge through a hydromechanical grease interceptor but it is required to discharge through a gravity grease interceptor. Reference: Section 1003.3, IPC 2012, as amended by the City of Tucson.
12/30/2014 KEN VAN KARSEN ELECTRICAL-COMMERCIAL REVIEW Completed

Final Status

Task End Date Reviewer's Name Type of Review Description
01/02/2015 CPIERCE1 REJECT SHELF Completed