Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T14CM06981
Parcel: 116205740

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T14CM06981
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/17/2014 JASON GREEN ENGINEERING REVIEW Approved
10/21/2014 MICHAEL ST. PAUL ZONING REVIEW Reqs Change Provide the three (3) foot setback to the garage.

Provide the legal description (Mercado District of Menlo Park Lot 52) on the plot plan and title sheet.

Provide the Mercado District approval stamp on all sheets,
10/22/2014 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Reqs Change PLAN REVIEW COMMENTS
Date: 10-22-14
Activity: T14CM06981
Address: 243 S. Avenida Del Palo Fiero
Applicant: Carol A. Griffith

This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

STRUCTURAL / FRAMING PLAN:
1. Provide structural calculations for building design. Structural review has not been completed.
2. Define SW-1 and C-1 on sheet S3.0.

SECTIONS - DETAILS:
3. Indicate materials of wall types indicated on sheet A102.
4. Include rammed earth wall type on sheet A102.

PLUMBING PLAN:
5. All construction drawings submitted after March 1, 2009 for one- or two-family dwellings require a solar water heating system, or future installation preparation with one of the following provisions: control and ¾"water piping; 3" metallic sleeve; or an accessible attic over the water heater, Ordinance 10549.
6. Specify the vent size at the kitchen sink and laundry fixtures, P3101.1.

MECHANICAL PLAN:
7. Provide Manual J/S/D calculations for the forced air unit in accordance with M1401.3, M1601.1.

ELECTRICAL PLAN:
8. Provide minimum 3/32" lettering per Unified Development Code.
9. On June 17, 2008, Mayor and Council unanimously voted to require all new residences to be solar ready for electric (PV). Starting July 1, 2009, all new single family homes or duplexes must include in the plans either a photovoltaic system or preparation for later installation of a PV system in order to receive a permit.
10. Electrical panels may not be located in storage closets, E3405.4
11. Designate the circuit number for each light fixture, receptacle, appliance, and equip disconnect on the electrical layout, E3703.5.
12. Show receptacle outlets at wall spaces 2' or more so that no point along the wall (excluding door openings) is more than 6' from a receptacle outlet. Refer to interior courtyard, dining room window area, downstairs bedroom, study, etc. Floor receptacles may be used at spaces in exterior walls occupied by fixed panels of glass, E3901.2.1, E3901.2.2(2).
13. Hallways of 10' or more in length require a receptacle, E3901.10.
14. Verify over current device capacity for automatic clothes dryer. Typically a 20 amp circuit would be insufficient unless it was a gas-fired appliance.

OUTDOOR LIGHTING CODE
15. Clarify the calculations associated with the outdoor lighting code. This lot is located in area E3. The maximum lumens for this lighting area is 55,000 per acre. Only a portion of that amount is permitted to be unshielded. Provide totals for both shielded and unshielded lighting.

INTERNATIONAL ENERGY CONSERVATION CODE:
16. Specify a "U" factor and solar heat gain coefficient of the windows and doors that meets or exceeds the requirements of N1102.1. The simplified prescribed energy value for climate zone 2B glazing is U=0.40 and skylights is U=0.65, the default SHGC is 0.25.
17. Specify high-efficacy lamps for at least 75% of all lighting fixtures, N1104.1.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Clayton.Trevillyan@tucsonaz.gov
Residential Plan Review