Permit Number: T14CM06475
Parcel: 136060690

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T14CM06475
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/12/2015 LOREN MAKUS ENGINEERING REVIEW Approved
02/17/2015 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
10/01/2014 DAVID RIVERA ZONING REVIEW Approved P&DS TRANSMITTAL


FROM: David Rivera, Principal Planner

PROJECT:
T14CM07475
2025 S Darling Avenue
Single Family Dwelling Use
Board of Adjustment review and approval required.



TRANSMITTAL: October 1, 2014


COMMENTS: the following comments are relative to an application for a Board of Adjustment (B of A) (UDC 3.10.1).


This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

01. COMMENT: Owner proposes to construct a new garage, porch and storage room along the south perimeter yard. The proposed wall height along the south perimeter yard is nine feet six inches (9'-6") from design grade. The minimum required setback based on the 9'-6" wall height from design grade is six feet four inches (6'-4"). The owner is requesting approval for a building setback of three (3) feet from the property line. A variance for a reduced building setback is required.
************************************************************************

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a).

The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 6.4.5.C.2.b.1.c). The minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b).


02. COMMENT: The owner proposes to construct the garage 15 feet from the front street perimeter property line. The required setback from the street perimeter property line is based on the greatest of 20 feet or one and one-half the height of the building wall from design grade. The wall height is 11'-6" from design grade. Based the proposed wall height adjacent to the street perimeter property line, the minimum of 20 feet from PL is required. The owner proposes 15 feet from the property line to the building and 16 feet from the back of sidewalk for the driveway. A B of A variance is required for the garage and driveway.
10/01/2014 DAVID RIVERA NPPO REVIEW Passed