Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T14CM06449
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/21/2015 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T14CM06449 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. FOUNDATION PLANS: 1. Indicate the direction of slope for the garage slab, R309.1. 2. Provide a Garage wall detail showing a 6" minimum separation of exterior siding or sheathing above finished grade, R317.1 item 5. This may require a design with concrete stems. 3. Show compliance with termite treatment, R318.2. 4. Notate the grade away from foundations with a minimum 6" fall within the first 10', R401.3. SECTIONS - DETAILS: 1. Show a minimum 1" ventilation clearance between ceiling insulation and roof sheathing over the wall and eave area if eave vents are used (detail #1/A2), R806.3. This may be accomplished w/ baffles. This method of ventilation provides appropriate upper and lower space vents allowing the reduced area calculation, thereby changing the required area from 1167 Sq. In. to 584 Sq. In. ELECTRICAL PLANS: 1. Smoke alarms are required outside each separate sleeping area, R314.3.2. 2. Show or notate the requirement for a carbon monoxide detector when the dwelling includes an attached garage or gas appliance, R315. 3. Provide a panel schedule showing wire size of each circuit or notate the wire size for each protection rating, E3702.2. 4. Appliances and equipment on general purpose circuits may not exceed 50% of the branch circuit rating, E3702.5. Change the circuit number on the general purpose receptacles shown on circuit #5 in the laundry and garage. 5. Show the Bathroom receptacle on a separate 20 AMP circuit (dedicated) with outlets at no other location, E3703.4. Separate this circuit from the exterior receptacles. 6. Show all garage receptacle outlets with GFCI protection including the ceiling receptacle, E3902.2. 7. Show or notate a disconnect means or a locking breaker for the water heater, E4101.5. OUTDOOR LIGHTING CODE 1. Show compliance with City of Tucson Outdoor Lighting Code section 3.1.2. Full cut-off fixtures are non-adjustable with no light above the horizontal plane (fixtures are completely closed above and to the lowest point of the lamp). Include all exterior fixtures on the property in the calculations, or change all proposed fixtures to full cut-off style. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Tucson is in climate zone 2B. The simplified prescribed energy values for glazing is U=0.40, skylights U=0.65, ceiling R=38 and walls R=13. Show the "R" values of insulation and the maximum "U" factors of the windows and doors on the plans as well as the solar heat gain coefficient SHGC minimum value of 0.25, N1102.1, or show overall compliance if using less than prescribed component values by providing a RES check calculation. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/30/2015 | KROBLES1 | OUT TO CUSTOMER | Completed |