Permit Number: T14CM06016
Parcel: 13014439B

Address:
4426 E 22ND ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T14CM06016
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/31/2014 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved
10/31/2014 LEERAY HANLY ELECTRICAL-COMMERCIAL REVIEW Completed
11/03/2014 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Chapman Honda
T14CM06016
Building Plan (2nd Review)

TRANSMITTAL DATE: November 3, 2014

1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Zoning has reviewed the building plans but cannot approve until a development package has been approved.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved development package. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
11/04/2014 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Revise detail 13/P5.0 to show the gas shutoff valve located immediately upstream of the sediment trap. Reference: Section 408.4, IFGC 2012. [Initial comment: Revise detail 13/P5.0 to show that it refers to water heaters WH-2 and WH-3 instead of electric water heater WH-1.]
2. Including the effect of the adjacent vertical wall and the two parapet walls, the effective roof area appears to be greater than 2,000 square feet and at a slope of 1/16" per foot, an 8" semi-circular gutter is required. Reference: Table 1106.6, IPC 2012. [Initial comment: The architectural roof plan shows a 5" gutter with a single downspout of unknown size serving the Detail Bay (161). Provide the size of the downspout and the slope of the gutter. Reference: Section 1106.6, IPC 2012.]
11/05/2014 ELEIBOL1 ENGINEERING REVIEW Approved See grading permit for conditions. Engineering will stamp plans after all other reviewers are approved.
11/05/2014 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
11/06/2014 KEN BROUILLETTE FIRE REVIEW Denied Unable to locate Hazardous Material Inventory Statement referenced in response letter.