Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T14CM05905
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/30/2014 | STEVE SHIELDS | ZONING | REVIEW | Denied | P&DS TRANSMITTAL FROM: Steve Shields, Lead Planner PROJECT: T14CM05905 422 N. Plumer Ave New SFR with detached carport TRANSMITTAL: September 22, 2014 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). based on a wall height of 10'-8" the required perimeter yard setback from the proposed SFR to the north property line is 7'-2", proposed is 4'-6". Based on a wall height of 10'-5" the required perimeter yard setback from the proposed carport to the north property line is 6'-11", proposed is 4'-6". Until the DDO is approved zoning cannot approve the building plans. |
| 10/14/2014 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 10-16-14 Activity: T14CM05905 Address: 422 N Plumer Ave Applicant: Chris Haggard This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. INCLUSIVE HOME DESIGN: 1. Indicate the path of egress from a public way. The elevation drawing or the site plan must show a ramped sidewalk if a paved driveway is not the accessible route, ANSI A117.1-1998 as amended. FOUNDATION PLAN: 2. Specify the maximum height of engineered backfill. 3. Provide soils report for engineered fill as specified on plan. 4. Specify horizontal offset from outside edge of footing to toe of adjoining slope for engineered fill. STRUCTURAL / FRAMING PLAN: 5. Provide diagonal bracing for the proposed carport or other means of lateral support. ELEVATIONS: 6. Specify height of building. SECTIONS - DETAILS: 7. Clarify the roof framing design that incorporates eave blocking for an unvented assembly. PLUMBING PLAN: 8. The Tucson Water policy adopted 7/13/12 limits the maximum demand for a 5/8" water meter to 15 GPM; Specify a minimum ¾" water meter for the proposed demand. Reference Tables P2903.6 and P2903.6 (1), IRC 2012. 9. All construction drawings submitted after June 1, 2010 for one- or two-family dwellings must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. Provide gray water segregation for the clothes washing machine with a gravity discharge that includes a stub out the exterior wall with a cleanout cap above grade colored purple. MECHANICAL PLAN: 10. Provide Manual J/S/D calculations for the forced air unit in accordance with M1401.3, M1601.1. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Clayton.Trevillyan@tucsonaz.gov Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/28/2014 | CPIERCE1 | REJECT SHELF | Completed |