Permit Review Detail
Review Status: Completed
Review Details: CELL TOWER/ANTENNAS
Permit Number - T14CM05714
Review Name: CELL TOWER/ANTENNAS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/02/2014 | CARL SCHULTZ | FIRE | REVIEW | Approved | |
| 09/03/2014 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | P&DS TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T14CM05714 229 East Valencia Road Cell tower antennas TRANSMITTAL: September 3, 2014 COMMENTS: the following comments are relative to an application for a Special Exception relative to cell tower antenna modifications. A Special Exception process and approval is required (UDC Section 4.3.2 and Table 4.8-4: Use Specific Standards 4.9.13.P and one of the following groups 4.9.4.I.1, & 4.9.13.E or 4.9.4.I.2 & .3 &.4.a or .4.b). A Special Exception has been approved (SE-14-38). The Special Exception is for 229 East Valencia Road. The permit and the drawings must be for the same address as the Special Exception. Revise the address on all drawings. The line work for the site plans and elevations is too light. Red doesn't reproduce well. Half tones also do not reproduce well. These drawings cannot be properly archived. Provide the Special Exception decision letter. Demonstrate compliance, with all the conditions stated in the letter, on the plans. a. The site plan shall clearly illustrate compliance with all conditions through the use of details, diagrams and/or notes. b. A copy of this decision letter shall be included with the site plan at the time of permit application submittal. c. Paint antennas and appurtenances to match existing color scheme. d. Wire ports shall be no higher or lower than the antenna panels. e. There shall be no footpegs added to the monopole. f. All cables shall be routed through the interior of the monopole, and shall not be visible. Provide the above requirements a., b., c., d., and f. as notes on the elevation plans. Provide a site plan in the set. |
| 09/03/2014 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Completed | |
| 09/03/2014 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. STRUCTURAL CALCULATIONS: THE PROFESSIONAL ENGINEER OF RECORD MUST SIGN AND DATE HIS SEAL ON THE CALCULATIONS. THE EXPIRATION DATE OF HIS ARIZONA LICENSE MUST ALSO BE NOTED BENEATH THE SEAL. |
| 09/03/2014 | MICHAEL ST. PAUL | PLANNING-CITY HALL | REVIEW | Denied | P&DS TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T14CM05714 229 East Valencia Road Cell tower antennas TRANSMITTAL: September 3, 2014 COMMENTS: the following comments are relative to an application for a Special Exception relative to cell tower antenna modifications. A Special Exception process and approval is required (UDC Section 4.3.2 and Table 4.8-4: Use Specific Standards 4.9.13.P and one of the following groups 4.9.4.I.1, & 4.9.13.E or 4.9.4.I.2 & .3 &.4.a or .4.b). A Special Exception has been approved (SE-14-38). The Special Exception is for 229 East Valencia Road. The permit and the drawings must be for the same address as the Special Exception. Revise the address on all drawings. The line work for the site plans and elevations is too light. Red doesn't reproduce well. Half tones also do not reproduce well. These drawings cannot be properly archived. Provide the Special Exception decision letter. Demonstrate compliance, with all the conditions stated in the letter, on the plans. a. The site plan shall clearly illustrate compliance with all conditions through the use of details, diagrams and/or notes. b. A copy of this decision letter shall be included with the site plan at the time of permit application submittal. c. Paint antennas and appurtenances to match existing color scheme. d. Wire ports shall be no higher or lower than the antenna panels. e. There shall be no footpegs added to the monopole. f. All cables shall be routed through the interior of the monopole, and shall not be visible. Provide the above requirements a., b., c., d., and f. as notes on the elevation plans. Provide a site plan in the set. |
| 09/11/2014 | CPIERCE1 | COMMUNICATIONS | REVIEW | Completed | PER JEFFREY SELIGMAN |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/12/2014 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |