Permit Number: T14CM05619
Parcel: 11931018A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T14CM05619
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/13/2014 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
Principal Planner

PROJECT: T14CM05619
3163 W Mockingbird Lane
Single Family Residence - HDZ and ERZ Overlay Compliance required

TRANSMITTAL DATE: September 4, 2014

DUE DATE: September 12, 2014

COMMENTS:

Previous Comment 01. Zoning has reviewed the plot plan for compliance with the zoning requirements for a single family home development in the SR zone.

Follow up to previous comment 2. Response to the zoning NPPO and engineering comments could not be found in re-submittal of the plans package. Zoning cannot approve the plot/site and building plans until all Engineering and Landscape reviewer's comment have been addressed via response document and compliance demonstrated on the plot/site plan sheet.

Previous Comment 02. The site is subject to compliance with the HDZ and ERZ requirements listed in UDC Article 5 Section 5.2 and 5.7 respectively. Zoning cannot approve Site and building plans until the HDZ and ERZ review have been completed and approved.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
10/14/2014 ANDREW CONNOR NPPO REVIEW Reqs Change The following was not addressed form the previous review:

The site is subject to compliance with the HDZ and ERZ requirements listed in UDC Article 5 Section 5.2 and 5.7 respectively. Zoning/NPPO cannot approve the building plans until the HDZ and ERZ review have been completed.

Include the following notes on cover sheet:

Vegetation Retention and Revegetation

Vegetation Retention

(1) Existing viable and transplantable trees with four inch or greater trunk diameter and cacti shall be preserved in their original locations, except for building sites and access and utilities serving building sites.

(a). When retention of the above trees and cacti in their original locations is not possible due to building site location, the trees and cacti shall be salvaged and replanted in areas requiring revegetation, whenever possible.

Revegetation

All cut or fillslopes that are no steeper than three horizontal to one vertical and all utility trenches or septic leaching fields that are not located in parking or driveway areas shall be revegetated in compliance with the following standards:

All plants used in revegetation shall be the same as the native vegetation on the site prior to grading or clearing or any adjacentsite; and,

2. Revegetation shall be accomplished with the following minimum standards for plants:

(a) Desert trees, a minimum of 15-gallon size with a minimum trunk diameter of two inches measured at the soil level, or large specimen cactus shall be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading; and,

(b) Seeds for trees, desert shrubs, and grasses shall be planted with a density adequate to control erosion and may use one of the following methods of planting: Raked into the soil with appropriate mulch materials; hydroseeding; anchored mulches; or established on jute, rolled straw, or similar material. Another method may be approved by PDSD.

Ensure that all Zoning and Engineering comments and concerns are addressed.

Additional comments may apply
10/16/2014 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
10/30/2014 ELIZABETH LEIBOLD ENGINEERING REVIEW Reqs Change Meeting with owner 31OCT14 to go over comments and assist with flood data for plans.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/03/2014 SHANAE POWELL OUT TO CUSTOMER Completed
11/03/2014 CPIERCE1 REJECT SHELF Completed