Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T14CM05617
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/27/2014 | DAVID RIVERA | ZONING | REVIEW | Approved | |
08/27/2014 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
08/28/2014 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Completed | |
08/28/2014 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
08/28/2014 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET A1: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. REVISE THE RESPONSIBILITIES TABLE. 2. SHEET D1; DEMOLITION SYMBOLS: SYMBOL K WAS NOT LOCATED ON THE PLAN. VERIFY. 3. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
08/28/2014 | ROBERT SHERRY | WATER | REVIEW | Completed | |
08/28/2014 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. The governing plumbing code is the 2012 International Plumbing Code. 2. Provide fixture descriptions for all plumbing fixtures. Reference: Section 402, IPC 2012 and Section 107.2.1, IBC 2012. 3. Provide an approved vacuum relief valve (not a vacuum breaker) for the scheduled bottom-fed water heater which is located above the fixture outlets. Reference: Section 504.2, IPC 2012. 4. Provide tempered water for the lavatories and public hand-washing sinks in restrooms using approved devices conforming to ASSE 1070. Reference: Sections 416.5 and 607.1.2, IPC 2012. |
08/28/2014 | MARTIN BROWN | FIRE | REVIEW | Approved | |
08/28/2014 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
09/16/2014 | CPIERCE1 | WWM | REVIEW | Completed |