Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T14CM05499
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/05/2014 | MARTIN BROWN | FIRE | REVIEW | Approved | |
11/05/2014 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Without the NFRC certification number for each fenestration component, the default U-values and SHGF values must be used in the COMcheck analysis. [Initial comment: Provide the NFRC fenestration product ratings on which the U-factors and SHGC values used on COMcheck have been based or use the appropriate default U-factors and SHGC values from Tables C303.1.3 (1) and C303.1.3 (2), IECC 2012. Show the required U-factors for the vertical glazing on the drawings. Reference: Section C303.1.3, IEC 2012.] |
11/05/2014 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
11/07/2014 | SPOWELL1 | BUILDING-COMMERCIAL | REVIEW | Needs Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
11/07/2014 | SHANAE POWELL | OUT TO CUSTOMER | Completed |
11/07/2014 | SHANAE POWELL | REJECT SHELF | Completed |