Review Date Reviewer's Name Type of Review Description Status Comments
08/25/2014 RONALD BROWN BUILDING-COMMERCIAL REVIEW Reqs Change SHEET SD2
1. Detail 4: Change the 5' dimension to 7'-0".
2. Detail 6:
a. Substitute the code reference 2009 ICC A117.1, Section 406 for the referenced PC/COT STD DTL 207. This detail is for DOT right of way accessible compliance only and may not be used for private projects.
b. Detectable warning strips are required only at transportation platforms only.
3. Any reference on this sheet to disabled or handicap persons should be changed to ACCESSIBLE.
4. Detail 7:
a. Provide the exact same accessible parking layout as shown on Sheet SD-2.1, the Partial Site Plan. Generic plans are not acceptable.
b. Note a flush condition for the sidewalk and the asphaltic paving.
c. Provide an 18'-0" dimension for the short side of the angled accessible parking space.
d. Note that the grade of 2% maximum in all directions is a requirement for all the areas of the accessible parking and aisles.
SHEET SD-2.1
5. How can the concrete accessible route be flush with the asphaltic paving and have a down ramp to the marked crossing? Please reconcile.
6. At note 3, reference changes as per comment 2a above.
7. At the most north easterly curb ramp, draw the flared sides at a 1:12 slope as required by detail 6/SD-2.
8. Provide an accessible passenger loading as required by the 2012 IBC, Section 1106.7 and the 2009 ICC A117.1, Section 503.
END OF REVIEW