Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T14CM04765
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/14/2014 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 10/17/2014 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 10/20/2014 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Provide NFRC fenestration product ratings for the U-factor and the SHGC values on COMcheck or use the appropriate default U-factor and SHGC values from Tables C303.1.3 (1) and C303.1.3.(2), IECC 2012. Reference: Sections C303.1.3 and R303.1.3, IEC 2012. [Second comment: The use of REScheck (especially with the 2009 IECC code) for the residential areas of the addition is not necessary; COMcheck can be used if the building areas are input appropriately. Provide NFRC fenestration product ratings for the U-factor and the SHGC values on COMcheck or use the appropriate default U-factor and SHGC values from Tables C303.1.3 (1) and C303.1.3.(2), IECC 2012. Reference: Sections C303.1.3 and R303.1.3, IEC 2012.] [Initial comment: Provide sufficient detail on the drawings to evaluate the energy compliance of the additions to the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. The information on the drawings shall agree with the component descriptions shown on the envelope compliance certificate. Note that the residential occupancy areas of the building addition are to meet the residential provisions of the IECC while the commercial occupancies are to meet the commercial provisions of the IECC. Reference: Sections C101.4.3, C101.4.6, C101.5, and C103.2, International Energy Conservation Code 2012.] |
| 10/21/2014 | STEVE SHIELDS | ZONING | REVIEW | Approved |