Permit Number: T14CM04633
Parcel: 117067290

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T14CM04633
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/24/2014 MARTIN BROWN FIRE REVIEW Approved
07/29/2014 JASON GREEN ENGINEERING REVIEW Reqs Change DATE: July 29, 2014
REVIEWER: Jason Green, CFM
ACTIVITY: T14CM04633 (Building Plan)

SUMMARY: Engineering Division of Planning & Development Services Department has received the building plan (T14CM04633). Engineering Division does not recommend approval of the building plan applications at this time. The following items need to be addressed:


BUILDING PLAN COMMENTS:

1) The building plan can not be approved by the Engineering Section until the last approved site plan and grading plan (DP12-0030) has been finalized. Currently the site/grading plan is in an EXPIRED status and there are outstanding grading inspection that still need to be called in. Contact Patricia Gehlen for further clarification on how to reactivate the EXPIRED site/grading plan application and what is required for the inspections with fees.
2) The building plan TI application can not be approved as shown with the proposed outdoor patio until a revised Development Plan Package is submitted for review and is approved by all relevant Sections of PDSD.
3) The building plan TI application can be approved once the existing Development Plan Package is finalized and the outdoor patio removed from the current building plan set.


GENERAL COMMENTS:

Please provide the revised building plan and or approved or finalized DP Package. Further comments may be generated upon resubmittal of the building plan review.

For questions or to schedule an appointment I can be reached at 837-4929.

Jason Green, CFM
Senior Engineer Associate
Engineering Division
Planning & Development Services
07/30/2014 LEERAY HANLY PLUMBING-COMMERCIAL REVIEW Completed oops
07/30/2014 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: 350 E. Congress Street #150
T14CM04633
Building Plan (1st Review)

TRANSMITTAL DATE: July 30, 2014

1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. The building plan can not be approved by the Zoning Section until the last approved site plan and grading plan (DP12-0030) has been finalized. Currently the site/grading plan is in an EXPIRED status and there are outstanding grading inspection that still need to be called in. Contact Patricia Gehlen for further clarification on how to reactivate the EXPIRED site/grading plan application and what is required for the inspections with fees.

3. The building plan TI application can not be approved as shown with the proposed outdoor patio until a revised Development Plan Package is submitted for review and is approved by all relevant Sections of PDSD.

4. Zoning will re-review the building plan on the next submittal to insure compliance with the approved development package. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
07/30/2014 LEERAY HANLY BUILDING-COMMERCIAL REVIEW Reqs Change Plan review has been completed and the following corrections are required. Please provide a written response to comments with plan re-submittal.

1) Errata: PP TS1 - Code study data is incorrect for a type IB building. Also be aware that this structure was designed as IIIB. See original shell drawings.
2) Errata: PP A1 - Reference to IBC section 803.9.1.1 is incorrect. There is no section 803.9.1.1 in the 2012 IBC. Do you mean section 808? Also be aware that the City of Tucson is not within a seismic zone that requires the splay wires shown in suspended ceiling detail. Most contractors in the city do not typically install them, but if they are shown on plan our inspectors will require it.

If there are questions regarding this review contact:

LeeRay
520-837-4906
LeeRay.Hanly@tucsonaz.gov
07/31/2014 LHANLY1 WATER REVIEW Completed
07/31/2014 LEERAY HANLY MECHANICAL-COMMERCIAL REVIEW Completed
07/31/2014 LHANLY1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Completed
07/31/2014 LEERAY HANLY ELECTRICAL-COMMERCIAL REVIEW Completed