Permit Number: T14CM04529
Parcel: 10512030D

Address:
4022 N ORACLE RD

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T14CM04529
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/02/2014 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved
09/03/2014 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
09/03/2014 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. The Wilkins model 700XL dual check valve (ASSE 1024) is listed for installations where potential health hazards do not exist (i.e. pollution). The submitted MSDS for the Microtech Phenom X Manual Pot & Pan Detergent indicates that ingestion may cause "abdominal discomfort, nausea, vomiting, and diarrhea"; definitely a potential health hazard (i.e. contamination). Provide a backflow prevention assembly listed to ASSE 1013 - a reduced pressure principle backflow assembly. Reference: Table 608.1, IPC 2012. [Initial comment: Provide the manufacturer's safety data sheet (MSDS) for the aluminum chloride contained in the chemical dispenser solution. Justify the use of a double check valve assembly for backflow protection. Reference: Section 608.13.9, IPC 2012.]
2. Hand sinks in the kitchen are allowed to connect to the sanitary waste system instead of the grease waste system only if each sink has a sign posted above it stating, "HANDWASH SINK ONLY! NO FOOD PREPARATION OR DISHWASHING ALLOWED." Reference: Section 1003.3, IPC 2012, as amended by the City of Tucson.
09/05/2014 LEERAY HANLY ELECTRICAL-COMMERCIAL REVIEW Completed