Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Permit Number - T14CM03468
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/09/2014 | JASON GREEN | ENGINEERING | REVIEW | Approved | June 9, 2014 FLOODPLAIN USE PERMIT NO.: T14OT00718 ADDRESS: 1021 S Colgate Dr Tucson, Arizona 85710 PROPERTY OWNER: Habitat for Humanity Tucson Inc. 3501 N Mountain Ave Tucson, AZ 85719 The applicant is authorized to use a portion of the FEMA Shaded Zone X 100 year floodplain per the Flood Insurance Rate Maps 04019C2303L, specifically described as: A portion of Parcel 134-24-3260, Yale Estates Lot 23 Blk 15 For the purpose of constructing a Single Family Residence. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. This floodplain use permit is issued with the following 8 conditions: 1) This project is located in a mapped regulatory floodplain per the FEMA Shaded Zone X 100 year floodplain per the Flood Insurance Rate Maps 04019C2303L. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) For purposes of this permit the following flood elevations shall be used for the building: Base Flood Elevation (BFE) = 1.0 feet Highest Adjacent Grade (HAG) Regulatory Flood Elevation (RFE) = 2.0 feet Highest Adjacent Grade (HAG) Building is to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE). 4) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the 1010/1015 inspection (P2S) and prior to finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the building as well as the identity and location of all other equipment/machinery servicing the building. 5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T14OT000718 FOR INFORMATION PLEASE CALL 791-5550." 6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 7) All work shall conform to the approved building plan, T14CM03468, which is made part of this permit. 8) This permit is specific to the improvements for 1021 S Colgate Dr as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year at the sole discretion of the City Engineer or designated representatives. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Habitat for Humanity Tucson LLC ADDRESS: 3501 N Mounatin Ave Tucson, Arizona 85719 PHONE: 520-326-1217 (EXPIRATION DATE) Month: 06 Day: 09 Year: 2015 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
| 06/10/2014 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 6-12-14 Activity: T14CM03468 Address: 1021 S Colgate Dr Applicant: Habitat for Humanity This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Correct reference to the 2006 IRC on sheet A5 2. Specify maximum height of controls within 15 to 48 inches of the floor (To include thermostat control sheet E1), 1003.9 ANSI 117.1-98. 3. Provide a complete set of notes on the plan to meet the Inclusive Home Design Ordinance 10463. 4. Clarify diameter of water supply line. Sheet SP1 indicates 1ΒΌ" and sheet P1 indicates 1". If you have any questions please contact: Clayton Trevillyan 520.837.4913 Clayton.Trevillyan@tucsonaz.gov Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/17/2014 | SHANAE POWELL | OUT TO CUSTOMER | Completed |
| 06/17/2014 | CPIERCE1 | REJECT SHELF | Completed |