Permit Number: T14CM03073
Parcel: 11706195A

Address:
33 S 6TH AV

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T14CM03073
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/20/2014 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved
08/29/2014 CPIERCE1 PLUMBING-COMMERCIAL REVIEW Reqs Change Use the correct type of backflow preventer for the calculations; a double check valve is not allowed for protecting the municipal water supply from this building. [Second comment: No specification sheets were included in this submittal but since the first check valve for a reduced pressure backflow preventer is required to have a 5 PSI pressure drop, it is unlikely that you will find a reduced pressure backflow preventer that has a 5 PSI pressure drop across two check valves and a reduced pressure zone.] [Initial comment: The water pressure calculations include a 5 PSI pressure drop due to the reduced pressure backflow preventers. Provide specification sheets from the manufacturer that supports that pressure drop. Reference: Section 604.1, IPC 2012.]
08/29/2014 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed

Final Status

Task End Date Reviewer's Name Type of Review Description
08/29/2014 AROMERO4 OUT TO CUSTOMER Completed