Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T14CM02862
Parcel: 11708102A

Address:
828 S RUSSELL AV

Review Status: Active

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T14CM02862
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
05/14/2014 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

FROM: Steve Shields, Lead Planner


PROJECT:
828 S. Russell Avenue
Permit garage converted to dwelling unit & sleeping quarters built without permits
T14CM02862


TRANSMITTAL:


COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1).


This site is located in the R-3 zone (UDC 4.7.13). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). Base on a wall height of 12'-8" the require perimeter yard setback to the north property line is 8'-5", proposed perimeter yard setback is 3'-8".

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a). Base on a wall height of 12'-8" the required street perimeter yard setback to Russell Avenue is 20'-0", proposed street perimeter yard setback is 0'-3".
05/14/2014 ANY ENGINEERING REVIEW Active
05/14/2014 SSHIELD1 NPPO REVIEW Passed
05/14/2014 ANY BUILDING-RESIDENTIAL REVIEW Active