Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T14CM02322
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/28/2014 | CPIERCE1 | BUILDING-COMMERCIAL | REVIEW | Needs Review | |
| 04/28/2014 | CPIERCE1 | FIRE | REVIEW | Needs Review | |
| 05/05/2014 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Plan review has been completed and the following corrections are required. Please provide a written response to comments with plan re-submittal. 1) Interlock of EF1 & EF2 to occupancy sensor does not provide for correct sequencing of operation with supply air from RTU 3. Fans may be on 24/7 timer set to operate whenever building is occupied, or they may be interlocked with RTU. Ref: IMC 403.2.1(4) If there are questions regarding this review contact: LeeRay 520-837-4906 LeeRay.Hanly@tucsonaz.gov |
| 05/06/2014 | LEERAY HANLY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Plan review has been completed and the following corrections are required. Please provide a written response to comments with plan re-submittal. 1) Show all wco's on dwv isometric plan. Ref IBC 107.2.1 2) Clarify note in Water Calculations referencing 7-5 of UPC and ΒΌ" /ft slope on service line. Ref: IBC 107.2.1 3) Provide cut-sheets indicating chemical dispenser at mop sink has internal back flow prevention, or specify adequate backflow protection. If there are questions regarding this review contact: LeeRay 520-837-4906 LeeRay.Hanly@tucsonaz.gov |
| 05/06/2014 | LEERAY HANLY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Plan review has been completed and the following corrections are required. Please provide a written response to comments with plan re-submittal. 1) Provide sequence of operation for restroom exhaust fans so that not more than 10% of supply air to these spaces is recirculated. Ref: IMC 403.2.1(4). 2) Return air notes indicate full 2000 cfm at registers. Coordinate return air at registers with required outside air for final balancing of equipment in field. Ref: IBC 107.2.1 3) Specify duct insulation in keynote 8 pp M1. Ref: IBC 107.2.1 If there are questions regarding this review contact: LeeRay 520-837-4906 LeeRay.Hanly@tucsonaz.gov |