Permit Number: T14CM02195
Parcel: 11502117A

Address:
210 E LESTER ST

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T14CM02195
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/17/2014 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. SHEET A2.0; SECOND FLOOR STAIR PLAN: THE IBC SECTION 1009.8 REQUIRES DOORS OPENING ONTO A LANDING SHALL NOT REDUCE THE LANDING TO LESS THAN 1/2 THE REQUIRED WIDTH. PER SECTION 1009.4 (EXCEPTION 1), THE REQUIRED WIDTH IS 36". DOES THE DOOR OPENING MEET THE CODE REQUIREMENT? VERIFY.
2. SHEET A2.0; SECOND FLOOR STAIR PLAN: THE IBC SECTION 1009.8 REQUIRES A FULLY OPEN DOOR SHALL NOT PROJECT MORE THAN 7" INTO A LANDING. DOES THE DOOR MEET THE CODE REQUIREMENT? VERIFY.
3. SHEET S1.0; STRUCTURAL NOTES: LIST THE REQUIRED CONCRETE COMPRESSIVE STRENGTH ON THE DRAWINGS.
4. SHEET S1.0; DETAIL 2: PROVIDE THE FOOTING SIZE ON THE DRAWING.
5. GENERAL: PROVIDE A CALCULATION ON THE DRAWINGS INDICATING THE REQUIRED WIDTH OF THE STAIR PER THE IBC SECTION 1005.3.1.
6. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
04/17/2014 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
04/18/2014 LEERAY HANLY MECHANICAL-COMMERCIAL REVIEW Passed
04/18/2014 LEERAY HANLY ELECTRICAL-COMMERCIAL REVIEW Passed
04/18/2014 LHANLY1 WATER REVIEW Passed
04/18/2014 STEVE SHIELDS ZONING REVIEW Approved
04/18/2014 LHANLY1 WWM REVIEW Passed
04/18/2014 LEERAY HANLY PLUMBING-COMMERCIAL REVIEW Passed
04/18/2014 JASON GREEN ENGINEERING REVIEW Approved
04/18/2014 MARTIN BROWN FIRE REVIEW Approved