Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T14CM02061
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/15/2014 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 05/15/2014 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Coordinate the envelope components with those shown on he drawings. [Initial comment: Provide energy code compliance calculations for the modifications to the building envelope; use the climate zone for Tucson. Provide sufficient detail on the drawings to evaluate the energy compliance of the additions to the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections C101.4.3, C101.5, and C103.2, International Energy Conservation Code 2012.] 2. Provide the mechanical energy code compliance certificate. [Initial comment: Show that the proposed HVAC system meets the requirements of Sections C403.2 and C403.3, IECC 2012 (e.g. provide the mechanical energy code compliance certification from COMcheck). Reference: Section C303.1, International Energy Conservation Code 2012.] 3. Comment not addressed. [Initial comment: Show that each heat pump meets the requirements of Section C403.3.1 (economizers) unless exempted by compliance with the efficiency requirements of Table C403.3.1 (2), IECC 2012.] |
| 05/15/2014 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Completed | |
| 05/15/2014 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Reqs Change | AT DETAIL 5/A9.0 Comment a: A 5'-0" clear floor space is required for a wheel chair turn around at the ends of both men's and women's shower stalls because the accessible shower is the last one at the end of the shower stall corridor. Please provide a 5'-0" clear turn around in front of the accessible shower. AT THE TYPICAL MOUNTING HEIGHTS SHEET A9.2 Comment 8: Please provide a dimension of 38" to 43" inches for the standing water dispenser spout height. REQUIRED SPECIAL INSPECTIONS Please review the list of special inspections provided in the CONDITIONS MENU and include the inspections not provided in your two part special inspection form if they are in fact required. Please provide a memo of those listed but not required and they will be renmoved for the list. END OF REVIEW |
| 05/15/2014 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved |