Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T14CM01767
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/20/2014 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 5-23-14 Activity: T14CM01767 Address: 145 W Compass Park Lane Applicant: Alex Enoch This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. The natural gas meter is shown to be located directly adjacent to the electric service meter. Indicate the minimum 36 inch separation required from sources of ignition. FLOOR PLAN: 2. Specify the finished floor elevation of the garage and patio floor surface. 3. Show the location of attic access min. 22"x30", R807. 4. Doors between a garage and a residence shall be self-closing minimum 20-minute fire-rated, R302.5.1. STRUCTURAL / FRAMING PLAN: 5. Specify continuous sheathing around perimeter of building or indicate the location of all braced wall panels, R403.1.6, R602.10.2.2. ELEVATIONS: 6. Specify the roof height above grade. 7. Conversion of square feet to linear feet is not consistent with the manufacturer specifications for the proposed ridge vent assembly, clarify. SECTIONS - DETAILS: 8. Provide a detail for paved surfaces adjacent to exterior framed walls and include the minimum 2" distance between the bottom of the stucco weep screed and paved surface, R703.6.2.1. 9. Eave vents require min. 1" clearance between ceiling insulation and roof sheathing, R806.3. PLUMBING PLAN: 10. Show the location of the gravity discharge stub-out for graywater collection from the clothes washing machine through the exterior wall, Ordinance #10579/11089 11. Clarify note number 23 on sheet P1.0. MECHANICAL PLAN: 12. Provide a mechanical plan layout consistent with the Manual J/D/S calculations provided. 13. Gas appliances require combustion air openings, M1701.1. ELECTRICAL PLAN: 14. Clarify the location of the counter receptacles in the kitchen area, E3901.4.1. Peninsula counter tops with a long dimension of 24" and a short dimension of 12" or greater shall have at least one receptacle, E3901.4.2/3. Receptacles shall not be located below a counter where the countertop extends more than 6" beyond its support base, E3901.4.5 INTERNATIONAL ENERGY CONSERVATION CODE: 15. Specify a "U" factor and solar heat gain coefficient of the windows and doors that meets or exceeds the requirements of N1102.1. The simplified prescribed energy value for climate zone 2B glazing is U=0.40 and skylights is U=0.65, the default SHGC is 0.25. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Clayton.Trevillyan@tucsonaz.gov Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/29/2014 | AROMERO4 | APPROVAL SHELF | Completed |
| 05/29/2014 | AROMERO4 | OUT TO CUSTOMER | Completed |