| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/28/2014 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 03/28/2014 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | The City of Tucson did not adopt ASHRAE Standard 62.1 for ventilation calculations and the 2012 IMC only references the ASHRAE Standard for the purpose of calculating the system ventilation efficiency (Ev). Provide calculations to show that the ventilation system is sized in accordance with Section 403.3, IMC 2012. |
| 03/28/2014 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Completed | |
| 03/28/2014 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 03/28/2014 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | 1. Need to provide a "Point of Use" water dispenser. |
| 03/28/2014 | CPIERCE1 | WWM | REVIEW | Passed | |
| 03/28/2014 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Provide tempered water for the lavatories located in restrooms using approved devices conforming to ASSE 1070. Reference: Sections 416.5 and 607.1.2, IPC 2012. |
| 03/28/2014 | CPIERCE1 | ENGINEERING | REVIEW | Needs Review | |
| 03/28/2014 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 03/28/2014 | RONALD BROWN | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |