Permit Number: T14CM01005
Parcel: 123171630

Review Status: Completed

Review Details: PLANS OK TO SUBMIT - RES

Permit Number - T14CM01005
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/25/2014 STEVE SHIELDS ZONING REVIEW Denied P&DS TRANSMITTAL


FROM: Steve Shields, Lead Planner

PROJECT:
1434 E. Drachman
New Single Family Residence
T14CM01005


TRANSMITTAL: February 25, 2014


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9 & .10.

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a).

1. Based on an exterior wall height of 22.83' the required front street perimeter yard setback from the proposed SFR to the street property line is 34.25', proposed front street perimeter yard setback is 23.5'.
2. Based on an exterior wall height of 24.5' the required front street perimeter yard setback from the proposed SFR to the street property line is 36.75', proposed front street perimeter yard setback is 27.5'.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).
3. Based on an exterior wall height of less than 24.5' the required east perimeter yard setback from the proposed SFR to the east property line is 16.34', proposed east perimeter yard setback 6.0'.
4. Based on an exterior wall height of less than 24.5' the required west perimeter yard setback from the proposed SFR to the west property line is 16.34', proposed east perimeter yard setback 6.0'.
02/25/2014 SSHIELD1 NPPO REVIEW Passed
06/04/2014 AROMERO4 ENGINEERING REVIEW Needs Review
06/04/2014 AROMERO4 BUILDING-RESIDENTIAL REVIEW Needs Review