Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T14CM00609
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/28/2014 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 2-28-14 Activity: T14CM00609 Address: 1621 N Dodge Blvd Applicant: Tucson Community Builders This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. INCLUSIVE HOME DESIGN: 1. Provide a complete set of notes on the plan to meet the Inclusive Home Design Ordinance 10463. 2. Provide an accessible route from the public way with a no-step entrance, 1003.2. Vertical changes in floor elevation may not exceed ¼ inch (½ inch when beveled), 1003.4. FLOOR PLAN: 3. Doors between a garage and a residence shall be self-closing minimum 20-minute fire-rated, R302.5.1. PLUMBING PLAN: 4. All construction drawings submitted after June 1, 2010 for one- or two-family dwellings must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. Provide gray water segregation for at least one (1) bathing fixture or clothes washing machine for all single story buildings. 5. All construction drawings submitted after March 1, 2009 for one- or two-family dwellings require a solar water heating system, or future installation preparation with one of the following provisions: control and ¾"water piping; 3" metallic sleeve; or an accessible attic over the water heater. MECHANICAL PLAN: 6. Provide a mechanical plan layout with duct sizes consistent with the calculations provided, M1401.3.. 7. Specify on the mechanical plan the equipment to be installed per calculations provided. ELECTRICAL PLAN: 8. At least one wall switch controlled light must be provided in attached garages, E3903.3. 9. Attached garages require at least one GFCI receptacle, E3901.9, E3902.2. OUTDOOR LIGHTING CODE 10. Include all exterior lighting proposed in the outdoor lighting calculation. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/03/2014 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 03/03/2014 | CPIERCE1 | REJECT SHELF | Completed |