Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T14CM00353
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/23/2014 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
01/27/2014 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Reqs Change | GENERAL 1. Need to provide structural drawings and calculations for the three canopies. SHEET SP1 2. Show the three canopies on the site plan. 3. Show the 1 hour fence separation at the easterly property line. Reference all section details. 4. Show all ramps on referenced Site Plan. 5. Correct the square footage conflict between Building Area: 2,027 and the total provided for the occupant load of 3357 s.f. SHEET A1.0 6. At note 20, confirm the actual existing slope for both ramps and include construction modifications on the drawings if the slope is in excess of 1:12 to the desired slope as required. SHEET A3.0 7. At detail 1, show the grab bars. SHEET S1.0 Correct the lettering size to COT standard of 3/32" actual for both upper and lower case and resubmit. END OF REVIEW |
01/28/2014 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
01/28/2014 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Clarify the work associated with the two lavatories in the restrooms. Demolition plan A0.0 calls for them to be demolished and keynote #12 on sheet A3.0 replaces them but nothing is shown on the plumbing plan, MP1.0. Reference: Section 107.2.1, IBC 2012. |
01/28/2014 | ROBERT SHERRY | WATER | REVIEW | Approved | |
02/04/2014 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Provide informtion to show compliance with the City of Tucson Outdoor Lighting Code. You can find the OLC on the City of Tucson Website. 2. Provide lighting compliance certificate to show compliance with the 2012 International Energy Conservation Code. 3. PP MP2.0 indicates restroom exaust fans to be switched with the light. This would not be compliant with 2012 IMC section 402.3. Interconnect exhaust with switch and AC unit supplying air to these restrooms or ensure that exhaust fans are always on while building is occupied (you may use a 24/7 time switch instead of a standard wall switch). |
02/05/2014 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | FROM: David Rivera Principal Planner PROJECT: T14CM00353 6042 E Speedway Blvd. Building Plan Review TRANSMITTAL DATE: February 5, 2014 DUE DATE: February 19, 2014 COMMENTS: 01. Zoning has reviewed the building plans and while they are in substantial compliance with the unapproved development plan the building plans cannot be approved at this time. Zoning will re-review the building plans on the next submittal to ensure compliance with the approved development package site plan. 02. The building plans depict an accessible ramp that was not depicted on the DP site plan. The DP must be revised to include the ramp. New reviewer signature from zoning is required on the DP site plan. (Over the counter approval once DP is revised prior to permits) If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
02/19/2014 | CPIERCE1 | REJECT SHELF | Completed |