Review Date Reviewer's Name Type of Review Description Status Comments
06/27/2014 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 6-30-14
Activity: T14CM00214
Address: 2209 E. Silver St
Applicant: Sharin Manion

This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

PLUMBING PLAN:
1. Show the required cleanout on the new building drain within 24" of the building, P3005.2.

MECHANICAL PLAN:
2. Provide Manual D calculations for duct design, M1601.1.

INTERNATIONAL ENERGY CONSERVATION CODE:
3. Provide additional information regarding the insulation material to be blown into the ceiling cavity that will provide the proposed value of R-38 at 9.25" thick.