Permit Review Detail
Review Status: Active
Review Details: REVISION - - 1ST
Permit Number - T14CM00037
Review Name: REVISION - - 1ST
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/22/2014 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | 1. Show Glu Lam beams on plan. 2. Provide structural calculations fo all new structural modifications. END OF REVIEW |
| 01/22/2014 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 01/22/2014 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 01/22/2014 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 01/24/2014 | LEERAY HANLY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 01/24/2014 | JASON GREEN | ENGINEERING | REVIEW | Approved | January 24, 2014 FLOODPLAIN USE PERMIT NO.: T14OT00106 ADDRESS: 3781 N Highway Dr Tucson, Arizona 85705 PROPERTY OWNER: Daveck Properties LLC PO Box 603 Tempe, AZ 85280 The applicant is authorized to use a portion of the FEMA Special Flood Hazard Area Zone AO1 floodplain per the Flood Insurance Rate Maps 04019C1669L, specifically described as: A portion of Parcel 103-09-018A For the purpose of an interior remodel to an existing conforming structure. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. Per the last approved Floodplain Use Permit and Elevation Certificate, T02OT01784, the existing building has been set to a finish floor elevation of 2.2 feet above highest adjacent grade. The building finals and survey stamped ELCERT confirms that the building was constructed per the site plan making it a conforming structure. All proposed work is to be interior to the building and no work shall be completed outside of the building without submitting new plans and permits to verify conformance with Chapter 26 of the Tucson Code. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Rumsey Architecture ADDRESS: 3541 S Calexico Ave Tucson, Arizona 85730 PHONE: 520-546-5800 CONTRACTOR: Robbins and Sons Construction LLC ADDRESS: 4120 N Flowing Wells Rd Tucson, Arizona 85705 PHONE: N/A (EXPIRATION DATE) Month: 01 Day: 24 Year: 2015 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |