Permit Review Detail
Review Status: Completed
Review Details: WALLS - ZONING/ENGINE
Permit Number - T14BU01100
Review Name: WALLS - ZONING/ENGINE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/06/2014 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 10/06/2014 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Passed | |
| 10/06/2014 | JASON GREEN | ENGINEERING | REVIEW | Approved | October 6, 2014 FLOODPLAIN USE PERMIT NO.: T14OT01267 ADDRESS: 7125 E Eli Pl Tucson, Arizona 85710 PROPERTY OWNER: Ramon Sepulveda The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the Rose Hill Wash delineation, specifically described as: A portion of Parcel 134-17-2580 For the purpose of constructing a 242 LF x 6-foot block wall with vents every 5-foot off center or at specific existing discharge points as shown on the site plan. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 8 conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the wall, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction of the wall within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) All work shall conform to the approved site plan sheets for the construction of the wall, which are made part of this permit. Specifically the wall is required to be vented every 5-feet off center to allow acceptance and discharge of onsite and offsite flows as to not adversely impact the adjacent properties. 4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T14OT01267 FOR INFORMATION PLEASE CALL 791-5550." 5) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 7) See the associated activity T14BU01100 8) This permit is specific to the improvements for 7125 E Eli Pl as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Ramon Sepulveda ADDRESS: 7125 E Eli Pl Tucson, Arizona 85710 PHONE: 520-885-0575 (EXPIRATION DATE) Month: 10 Day: 06 Year: 2015 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |