Permit Review Detail
Review Status: Completed
Review Details: POOL - SPA
Permit Number - T14BU00157
Review Name: POOL - SPA
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/06/2014 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Approved | |
| 02/06/2014 | JASON GREEN | ENGINEERING | REVIEW | Approved | February 7, 2014 FLOODPLAIN USE PERMIT NO.: T14OT00167 ADDRESS: 6325 E Julia St Tucson, Arizona 85710 PROPERTY OWNER: Dale Shaun 6325 E Julia St Tucson, Arizona 85710 The applicant is authorized to use a portion of the FEMA Shaded Zone X 100-year floodplain per the Flood Insurance Rate Maps 04019C2303L, specifically described as: For the purpose of installing electrical equipment to a new pool. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and are bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, or local regulation. This floodplain use permit is issued with the following 6 conditions: 1) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 2) The topography of the site shows an elevation of 2591 NAVD. Per the aerial and past permits there is a 5 foot high block wall surrounding the proposed pool area. Due to the wall and the insignificant amount of flow crossing the property it has been determined that no elevation of the pool electrical equipment is required. However it is recommended that the equipment be protected from ponding water due to roof run-off and ponding in the yard. 3) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T14CM00167 FOR INFORMATION PLEASE CALL 791-5550." 4) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 5) All work shall conform to the approved site plan, which is made part of this permit. T14BU00157 6) This permit is specific to the improvements for 6325 E Julia St as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning & Development Services Department, Engineering Section. APPLICANT NAME: Valley Oasis ADDRESS: 3321 N Freeway Tucson, Arizona 85705 PHONE: 520-293-5818 CONTRACTOR: Valley Oasis ADDRESS: 3321 N Freeway Tucson, Arizona 85705 PHONE: 520-293-5818 (EXPIRATION DATE) Month: 02 Day: 07 Year: 2015 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
| 02/07/2014 | JGREEN2 | ZONING | REVIEW | Passed |