Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T13SE00022
Parcel: Unknown

Review Status: Completed

Review Details: REZONING - IPC

Plan Number - T13SE00022
Review Name: REZONING - IPC
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/27/2013 STEVE SHIELDS ZONING REVIEW Completed PDSD TRANSMITTAL

TO: Rezoning Division
Re: Acceptance of Information for Plan Compliance (IPC)

FROM: Steve Shields
Lead Planner

PROJECT: AT&T New Cell Tower
1740 E. Fort Lowell Road - C-1
Special Exception - SE-13-22

TRANSMITTAL: February 27, 2013

1. The proposed "Wireless Communication, limited to wireless communication towers and antennae", located on parcels 113-07-142B, zoned C-1. The use falls under UDC Table 4.8-4: Permitted Uses - Commercial and Mixed Use Zones - Permitted as Special Exception Use. The following Use Specific Standards apply: 4.9.4.I.2, .3 & .7 and 4.9.13.O.

2. The following dimensional Standards apply see UDC Table 6.3-4.A DIMENSIONAL STANDARDS FOR THE C-1, C-2, C-3, OCR-1, & OCR-2 ZONES

a. Minimum site area = 0 Sq. Ft.
b. Proposed site area = Not Provided (Existing)
c. Maximum building height allowed = 30 feet
d. Building height proposed = N/A (No new buildings proposed)

3. The submitted plan, showing the proposed Wireless Communication is acceptable to continue the review for the zoning examiner's report.

4. The following items need to be noted at this time:
a. The proposed location appears to eliminate vehicle parking. The last approved site/development plan was not provided therefore Zoning was not able to verify that minimum number of vehicle parking spaces is provided.
b. Per UDC Section 7.4.6.2.b The vehicle parking space shown directly north of the enclosure is required to be ten (10) feet wide. The width of this parking space is not provided on the plan.
c. Per UDC 6.6.2.J In nonresidential zones, walls or fences, as permitted in Section 6.6.2.I above, may exceed the height standards, provided the wall or fence complies with side and rear yard standards applicable to buildings on the site. That said per UDC Table 6.3-4.A DIMENSIONAL STANDARDS FOR THE C-1, C-2, C-3, OCR-1, & OCR-2 ZONES the required perimeter yard setback to the R-2 zoned property to the south is twelve (12) feet for the proposed 8'-0" enclosure wall. As a perimeter yard setback dimension was not provided and based on dimensions provided on drawing T669-LL 04 the proposed eleven (11) feet setback does not meet this requirement.



If you have any questions about this transmittal, please call Steve Shields, (520) 836-4956 or email Steve.Shields@tucsonaz.gov.
03/04/2013 LAITH ALSHAMI ENGINEERING REVIEW Completed Laith Alshami, Engineering and Floodplain Review, 03/04/2013,

TO: Peter McLaughlin FROM: Laith Alshami, P.E.
Rezoning Section Engineering


SUBJECT: AT&T Mobility Site Number T669-LL - 1740 E Fort Lowell Road
Special Exception Case SE-13-22, T13S, R14E, SECTION 31
Reference: T12PRE0092

RECEIVED: Special Exception Preliminary Development Plan on February 23, 2013

The Preliminary Development Plan appears to have adequate Engineering and Floodplain related information to be forwarded to the rezoning examiner. No special conditions are offered.
03/04/2013 KEN BROUILLETTE FIRE REVIEW Approv-Cond Codes should be updated to 2012 editions for International
03/05/2013 MPADILL1 COMMUNITY PLANNING REVIEW Completed PLANNING & DEVELOPMENT SERVICES DEPARTMENT
SE-13-22 IPC AT&T - Fort Lowell Road
Special Exception in the C-1
Cragin-Keeling Area Plan (CKAP) and General Plan
2/28/13 rjh

Background: This a special exception request to allow for the installation of a Wireless Communication Facility (WCF) in the form of a stealth 65 foot monopalm with ground equipment and masonry screen walls in a shopping center zoned C-1 Neighborhood Commercial. The Shopping Center is located at the southwest corner of Campbell Avenue and Ft. Lowell Road. The specific WCF location is in the southwest corner of the Shopping Center in an existing parking lot. This location does not meet the minimum setback of two times the pole height from adjacent residential property. Maintenance to the wireless communication facility will use the existing circulation system in the parking lot.

According to the Major Streets and Routes Plan, Campbell Avenue and Ft. Lowell Road are both designated arterial streets. Campbell Avenue is also designated a Gateway Route. The proposed WCF is located outside of the 400 foot Gateway buffer.

Surrounding Zoning and Land Use: The Shopping Center that would contain the proposed WCF continues to the north and east of the special exception site and is zoned C-1 Neighborhood Commercial. To the west of the special exception site is an office/shopping center zoned C-1 Neighborhood Commercial. To the south, southeast and southwest of the special exception site is apartment and duplex residential development in the R-2 Medium Density Residential zone. The nearest residential unit to the proposed new WCF location is directly adjacent to the south southwest, approximately 60 feet from the actual monopalm location.

Rezoning Presubmittal Meeting: The applicant attended rezoning presubmittal conference meetings on 1/9/13. Issues raised at the meeting included; potential parking uses at this center, compatibility and graffiti abatement, urban heat island effect/landscaping, and possible floodplain use permit/elevation certificate.

Neighborhood Meeting:
The neighborhood meeting was held on January 3, 2012. The sign-in sheet shows representatives for the rezoning request were present at the meeting, two council representatives from Ward 3 and two interested citizens. The submitted minutes state that no objections to the proposed development were raised.

Land Use Policies: Policy is provided by the Cragin-Keeling Area Plan (CKAP) and the General Plan.

Cragin-Keeling Area Plan (CKAP). The main goal of the CKAP is to encourage new non-residential development and redevelopment that is cohesive and integrated with adjacent non-residential uses while preserving and enhancing the existing residential character of the area. Non-residential Policy 2 supports a mix of non-residential and higher density residential uses along arterial streets as shown on the Land Use Map when proposed development is compatibly designed with adjacent less intense uses. General Design Guideline 1 calls for appropriate design elements and buffering techniques to mitigate the potential negative impacts of more intense development on established neighborhoods.

General Plan. Element 2 (Land Use) Policy 3 supports the protection of established residential neighborhoods by supporting compatible development, which may include appropriate nonresidential uses. Supporting Policy 3.9 supports nonresidential uses, where the scale and intensity of uses will be compatible with adjacent uses. Policy 5 supports appropriate locations for commercial uses, with priority for redevelopment in the existing urbanized area. Supporting Policy 5.5 encourages the redevelopment and/or expansion of current strip commercial development that will improve traffic flow, pedestrian mobility and safety, and streetscape quality when: 1) the project stabilizes and enhances the transition edge when adjacent to existing and future residential uses; and, 4) screening and buffering of adjacent residential properties can be provided on site.

Element 4 (Community Character and Design), Policy 3.7 requires that, if possible, telecommunications facilities be located, installed and maintained to minimize visual impacts and preserve views. Visual impacts are key consideration during the review process. Policy 4.6 promotes the coordination of efforts of government, private developers and utility firms to improve the appearance of above-ground utilities and structures. Policy 5 promotes neighborhood identity and visual character. Supporting Policy 5.3 supports redevelopment projects that reflect sensitivity to site and neighborhood conditions. Action 5.5A is to consider incentives for telecommunications providers to install infrastructure not only in newer areas, but also in older neighborhoods to increase opportunities for all citizens to have access to high-tech telecom services. Policy 6 promotes quality in design for all development. Supporting Policy 6.1 promotes an environmentally sensitive design that protects the integrity of existing neighborhoods, complements adjacent land uses, and enhances the overall function and visual quality of the street, adjacent properties, and the community.

Plan Compliance and Recommendation:

The stealth monopalm is proposed at a height of 65 feet and will be visible from the surrounding residential neighborhood, through there are existing palms and other trees in the surrounding area that will help this stealth feature to blend into the existing environment. General Plan and Cragin-Keeling Area Plan (CKAP) policy direction allow for the development of a stealth monopalm with ground equipment and masonry screen walls on the proposed Special Exception site; though a residential unit appears to be located within striking distance should the WCF fall in the right direction. A plan amendment is not required. Staff recommends that the rezoning application be distributed for further processing.

Staff believes rezoning conditions can be used to address compatibility concerns. Anticipated conditions include:

" Communication tower shall be stealth in design, disguised as a monopalm;
" Monopalm shall not exceed 65 feet in height and address residential setback concerns;
" Monopalm design shall include crown, pineapple, and cladding of pole from pineapple to ground surface;
" Ground equipment to be located within an enclosed shelter;
" Monopalm design for fronds must vary in length;
" Replacement of lost/damaged fronds to be completed within ten working days of observation;
" Monopalm cladding shall not be painted on, cladding panels must be painted light/shade cameo with a color sample provided;
" Monopalm set-up shall allow for 2nd carrier to co-locate in pineapple under crown;
" Frond colors shall be close to living palms with color sample provided.


S:\UPDfiles\DevRev\CASE_REVIEW\SP-EXCPT\SE 2013\SE-13-22 IPC AT&T - Fort Lowell Road