Plan Number: T13PI00026
Parcel: Unknown

Address:
3950 E JUAREZ ST

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T13PI00026
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2014 RICHARD LEIGH DOT ENGINEERING REVIEW Denied December 31, 2013


SUBJECT: CENTRAL TUCSON DES OFFICE,
PIA Plan T13PI00026

PROJECT REVIEWER: Zelin Canchola,
Permits and Codes Section


RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed prior to the next subsequent review submittal. Please return redlined drawings with next submittal.


1. Include the plan number U-2013-022 in the title block of each sheet

2. Include Planning and Development Services Department PIA activity number T13PI00026 on cover sheet

3. Sheet 1 of 7 - Replace "Traffic Engineering" with "TDOT Permits and Codes"

4. Sheet 3 of 7 - Remove word "Alley"

5. Verify comment from PDSD Engineering - Verification of Discharge to Juarez Street does not adversely impact street.

6. Sheet 4 of 7 - Reference to detail B/5 should be B/6

7. Sheet 6 of 7 - Modify scupper detail to reflect 3.5 foot buffer between curb and sidewalk.

Address comments on redline plan set. Responses can be noted on redline drawings. Refer to redline plans for comment details.

If you have any questions I can be reached at 837-6659 or zelin.canchola@tucsonaz.gov
01/08/2014 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Denied We have reviewed this plan and have the following comments:

1. Page 1 - Paving Note 11 - Please change mMedian Island Maintenance phone number to 791-3154 and change Paul Rosenboom's phone number to 837-6796.
2. Sheets 3 and 4 - Plans show curb access ramps and there is a note to construct new access ramps in the keynotes but the number is not shown on the plans. Please add note #6 to the plans.
3. Page 6 - Detail A- B - D- the max cross slopw allowed for a sidewalk scupper is 2%. Please indicate this on the plans.

No further comments.

Reviewed by Marc Avery
01/14/2014 IMEDINA1 UTILITY CLEARANCES COT STREETS DIVISION Completed
01/14/2014 IMEDINA1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Completed
01/14/2014 IMEDINA1 UTILITY CLEARANCES PC WASTEWATER MGMT Completed
01/14/2014 IMEDINA1 UTILITY CLEARANCES QUEST COMMUNICATION Completed
01/14/2014 IMEDINA1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Completed
01/14/2014 IMEDINA1 UTILITY CLEARANCES COX COMMUNICATION Completed
01/14/2014 IMEDINA1 UTILITY CLEARANCES SOUTHWEST GAS CORP Completed
01/14/2014 IMEDINA1 UTILITY CLEARANCES EL PASO NATURAL GAS Completed
01/14/2014 IMEDINA1 UTILITY CLEARANCES KINDER MORGAN ENERGY Completed
01/15/2014 BLANCA ESPINO PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
01/15/2014 BLANCA ESPINO PIA COORDINATOR OUT TO CUSTOMER Completed
12/09/2013 JOSE ORTIZ DOT TRAFFIC REVIEW Denied PLAN #: U-2013-022
ACTIVITY NUMBER: t13pi00026
PROJECT NAME: Central Tucson DES Ofc
PROJECT ADDRESS: Juarez St. & Alvernon
PROJECT REVIEWER: Matthew Geweke, Traffic Eng Tech Ph: 837-6665

Resubmittal Required:
Traffic Engineering does not recommend approval these plans at this time. Plan is required for re-submittal.

The following items must be revised or added to the plan. Please include a brief response letter with the next submittal that states how all comments have been addressed and the original redlined set of plans for back checking.

The following items must be revised or added to the plan:

1. Please update/correct striping note #6 on Sht. 2 (also see attached)

2. Before the WG6 can be striped, there will need to be some WS6 oblit, also some oblit may be needed across Juarez St.
Then reseal the pavement scarring with standard fog seal treatment as described in the notes.

3. Please refresh the WS6 stripe abutting the right turn bay.

4. Please place the "Right Lane" R3-5f above the R3-5r sign.

If you wish to email me (Matthew.Geweke@tucsonaz.gov) with PDF's of original redlines and the revised plan sheets of these requested changes prior to the next submittal, we could expedite the Traffic Eng. acceptance of these plans.
12/11/2013 GARY WITTWER DOT LANDSCAPE REVIEW Approved