Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T13PI00026
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/02/2014 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | December 31, 2013 SUBJECT: CENTRAL TUCSON DES OFFICE, PIA Plan T13PI00026 PROJECT REVIEWER: Zelin Canchola, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed prior to the next subsequent review submittal. Please return redlined drawings with next submittal. 1. Include the plan number U-2013-022 in the title block of each sheet 2. Include Planning and Development Services Department PIA activity number T13PI00026 on cover sheet 3. Sheet 1 of 7 - Replace "Traffic Engineering" with "TDOT Permits and Codes" 4. Sheet 3 of 7 - Remove word "Alley" 5. Verify comment from PDSD Engineering - Verification of Discharge to Juarez Street does not adversely impact street. 6. Sheet 4 of 7 - Reference to detail B/5 should be B/6 7. Sheet 6 of 7 - Modify scupper detail to reflect 3.5 foot buffer between curb and sidewalk. Address comments on redline plan set. Responses can be noted on redline drawings. Refer to redline plans for comment details. If you have any questions I can be reached at 837-6659 or zelin.canchola@tucsonaz.gov |
| 01/08/2014 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | We have reviewed this plan and have the following comments: 1. Page 1 - Paving Note 11 - Please change mMedian Island Maintenance phone number to 791-3154 and change Paul Rosenboom's phone number to 837-6796. 2. Sheets 3 and 4 - Plans show curb access ramps and there is a note to construct new access ramps in the keynotes but the number is not shown on the plans. Please add note #6 to the plans. 3. Page 6 - Detail A- B - D- the max cross slopw allowed for a sidewalk scupper is 2%. Please indicate this on the plans. No further comments. Reviewed by Marc Avery |
| 01/14/2014 | IMEDINA1 | UTILITY CLEARANCES | COT STREETS DIVISION | Completed | |
| 01/14/2014 | IMEDINA1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Completed | |
| 01/14/2014 | IMEDINA1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | |
| 01/14/2014 | IMEDINA1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Completed | |
| 01/14/2014 | IMEDINA1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Completed | |
| 01/14/2014 | IMEDINA1 | UTILITY CLEARANCES | COX COMMUNICATION | Completed | |
| 01/14/2014 | IMEDINA1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Completed | |
| 01/14/2014 | IMEDINA1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Completed | |
| 01/14/2014 | IMEDINA1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Completed | |
| 01/15/2014 | BLANCA ESPINO | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 01/15/2014 | BLANCA ESPINO | PIA COORDINATOR | OUT TO CUSTOMER | Completed | |
| 12/09/2013 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Denied | PLAN #: U-2013-022 ACTIVITY NUMBER: t13pi00026 PROJECT NAME: Central Tucson DES Ofc PROJECT ADDRESS: Juarez St. & Alvernon PROJECT REVIEWER: Matthew Geweke, Traffic Eng Tech Ph: 837-6665 Resubmittal Required: Traffic Engineering does not recommend approval these plans at this time. Plan is required for re-submittal. The following items must be revised or added to the plan. Please include a brief response letter with the next submittal that states how all comments have been addressed and the original redlined set of plans for back checking. The following items must be revised or added to the plan: 1. Please update/correct striping note #6 on Sht. 2 (also see attached) 2. Before the WG6 can be striped, there will need to be some WS6 oblit, also some oblit may be needed across Juarez St. Then reseal the pavement scarring with standard fog seal treatment as described in the notes. 3. Please refresh the WS6 stripe abutting the right turn bay. 4. Please place the "Right Lane" R3-5f above the R3-5r sign. If you wish to email me (Matthew.Geweke@tucsonaz.gov) with PDF's of original redlines and the revised plan sheets of these requested changes prior to the next submittal, we could expedite the Traffic Eng. acceptance of these plans. |
| 12/11/2013 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approved |