Plan Review Detail
Review Status: Completed
Review Details: PIA - RESUBMITTAL
Plan Number - T13PI00024
Review Name: PIA - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/18/2015 | LINZUNZA | UTILITY CLEARANCES | COT STREETS DIVISION | Completed | |
| 05/18/2015 | LINZUNZA | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Completed | |
| 05/18/2015 | LINZUNZA | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | |
| 05/18/2015 | LINZUNZA | UTILITY CLEARANCES | QUEST COMMUNICATION | Completed | |
| 05/18/2015 | LINZUNZA | UTILITY CLEARANCES | COX COMMUNICATION | Completed | |
| 05/18/2015 | LINZUNZA | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Completed | |
| 05/18/2015 | LINZUNZA | UTILITY CLEARANCES | EL PASO NATURAL GAS | Completed | |
| 05/18/2015 | LINZUNZA | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Completed | |
| 06/15/2015 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approv-Cond | |
| 06/15/2015 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
| 06/15/2015 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed | |
| 07/16/2014 | LINZUNZA | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 07/22/2014 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | In my last review I noted that if you were to place private irrigation lines under public roadways you would be required to have an easement. This process has been discontinued and you can no longer do this. The irrigation systems will need to be re-designed. Please coordinate with the signage plans. Trees must be set back 50 feet from a stop sign within the ROW for the approaching vehical. This is a major safety issue. I am not sure that the City is required to notify you of all utility work - that would be up to the Director. |
| 09/19/2014 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Denied | September 19, 2014 PROJECT NAME: La Estrancia De Tucson - Camino Boleadoras & Via Bombachas (2nd Submittal) PLAN #: I-2006-036 ACTIVITY NUMBER: T13PI00024 PROJECT REVIEWER: Simon Ramos, EIT, Traffic Engineering, City of Tucson DOT The Signing and Striping Section has completed the reviewed of the PIA plan and does not recommend approval at this time. The following comments need to be addressed in the subsequent plan submittal. Please return redlined drawings with next submittal and reference PIA activity number on all correspondences. 1. On page 1 of 3, Striping Notes #6 and #7, DELETE "hot-sprayed". 2. On page 1 of 3, Striping Notes #8 - DELETE "following control points that have been set no more than 50 feet apart along the lines to be striped in tangent section of a road where the pavement marking pattern does not change, control points can be set at 200 feet apart." 3. On page 1 of 3, Striping Notes #11 - Fix indent. 4. On page 1 of 3, Striping Notes #15 - DELETE all, it is a repeat. 5. On page 2 of 3, ADD "Shop drawings for all signs including street name signs shall be submitted to Traffic Engineering (Diahn Swartz 520-791-4259) for approval before fabrication." in General Notes. 6. On page 2 and 3 of 3, DELETE all "No Parking Signs". 7. On page 2 of 3, REPLACE "W6-2" Sign with "W6-1" Sign as noted on red-lines. 8. On page 2 of 3, REPLACE "PER STD. DTL 5-14" with "Pavement Marking Design Manual Sheet 5-14" 9. On page 2 and 3 of 3, Indicate YS4 installed 1 foot offset from curb. 10. On page 2 of 3, Speed Limit 30 MPH per Signing Notes and dimensions are 24x30.. 11. On page 2 and 3 of 3, Indicate all signing dimensions. 12. On page 2 and 3 of 3, REMOVE all "Stop Signs" where indicated on red-lines. 13. On page 2 of 3, Mount "Bike Route" sign on same post of "Speed Limit" sign as indicated on red- lines. 14. On page 2 of 3, ADD signing where indicated on red-lines. 15. On page 3 of 3, REMOVE all pavement markings on Via Bombachas and Via Pampas Morenas. 16. On page 3 of 3, Improve visibility of street name signs by locating closer to intersection per red- lines. 17. On page 3 of 3, REMOVE "R3-8LR" signs as indicated on red-lines. 18. On page 3 of 3, Need Guidance that road does not continue to Julian Wash. Suggestion on red- lines. (4 x OM4-3). 19. Fix station 28+07.57? Please Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6678 or Simon.Ramos@tucsonaz.gov |
| 10/17/2014 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Approved |