Plan Number: T13PI00021
Parcel: Unknown

Address:
1527 N BROWN AV

Review Status: Completed

Review Details: PIA - RESUBMITTAL

Plan Number - T13PI00021
Review Name: PIA - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/08/2016 LINZUNZA UTILITY CLEARANCES COT STREETS DIVISION Denied
06/08/2016 LINZUNZA UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Denied
06/08/2016 LINZUNZA UTILITY CLEARANCES PC WASTEWATER MGMT Denied
06/08/2016 LINZUNZA UTILITY CLEARANCES QUEST COMMUNICATION Denied
06/08/2016 LINZUNZA UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied
06/08/2016 LINZUNZA UTILITY CLEARANCES COX COMMUNICATION Denied
06/08/2016 LINZUNZA UTILITY CLEARANCES SOUTHWEST GAS CORP Denied
06/08/2016 LINZUNZA UTILITY CLEARANCES EL PASO NATURAL GAS Denied
06/08/2016 LINZUNZA UTILITY CLEARANCES KINDER MORGAN ENERGY Denied
06/13/2016 ZELIN CANCHOLA DOT TRAFFIC REVIEW Approved
06/21/2016 GARY WITTWER DOT LANDSCAPE REVIEW Approved
06/23/2016 RICHARD LEIGH DOT ENGINEERING REVIEW Denied June 21, 2016

SUBJECT: Haciendas at Wrightstown II

PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section

RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval at this time. The following comments need to be addressed prior to in the subsequent review submittal. Please return redlined drawings with next submittal.


Provide complete roadway centerline data for Ohana Place.

Sheet 2 of 3: Revise water harvesting curb opening detail to reflect TDOT Water Harvesting Curb Cut Detail, see attached. (wttps://www.tucsonaz.gov/tdot/landscape) The maximum curb opening width is 2 feet. Additionally, label openings with a keynote.

Sheet 2 of 3: revise drawing to eliminate the proposed depressed wedge curb section at Sta. 3+10, RT Ohana Place. Wedge curb is designed to be mounted and having the depressed cub may allow for flows to enter the easement area.

Sheet 2 of 3: Revise detail A "Typical H/C Access Ramp" to indicate the placement of vertical curb at back of ramp.

Sheet 2 of 3: Revise drawing to indicate the placement of a curb access ramp per ADOT Sidewalk Ramp Type 2 or similar where the sidewalk terminates on the east side of Ohana Place.

Sheet 2 of 3: Revise drawing to locate the proposed curb access ramp at Sta. 6+13, LT Ohana Place so it will be in line with the east west running sidewalk.

Sheet 2 of 3: Remove proposed crosswalk striping; crosswalk striping is not required on residential Streets.

Sheet 3 of 3: Provide a roadway section that represents the roadway section where sidewalk will not be provided on the south side of Ohana Place. Additionally, indicate the final surface treatment of the area where sidewalk will not be provided.

Provide complete details and sections for the drainage opening at the basin outlet.

Provide a dimensioned detail for wedge curb transitions at scuppers and curb access ramps.

Please Refer to redline plans for additional comments and comment details.
06/24/2016 LINZUNZA DOT PERMITS & CODES REVIEW Denied Date: June 23, 2016
PROJECT NAME: Haciendas at Wrightstown Lots 13-25 and Common Area "A"
PLAN #: I-2013-019
ACTIVITY NUMBER: T13PI00021
PROJECT REVIEWER: David Stiffey, Construction Inspection Supervisor, City of Tucson DOT/Eng.

Comments:

The TDOT Engineering Inspection Unit has completed the review of the PIA plans and recommends denial/resubmittal. The following comments need to be addressed in the subsequent plan submittal. Please return redlined drawings with next submittal and reference PIA activity number on all correspondences.

Sheet 2: My note was in reference to the driveway detail. The note is that in the event that they have sidewalk adjacent to the wedge curb then the curb wings at the driveway depression can only be a minimum of 4' but may also be longer than that, depending on the slope ratio because if the sidewalk is adjacent to the curb, then the wings for the driveway depression have to be 12:1 ratio maximum.

If you have any questions, I can be reached at (520) 403-0970 or David.Stiffey@tucsonaz.gov
06/27/2016 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Approved
06/27/2016 LINZUNZA PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSADOR Completed
06/27/2016 LINZUNZA PIA COORDINATOR OUT TO CUSTOMER Completed