Plan Review Detail
Review Status: Stopped
Review Details: PIA - SUBMITTAL
Plan Number - T13PI00021
Review Name: PIA - SUBMITTAL
Review Status: Stopped
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2016 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Stop | |
| 10/29/2013 | ANY | PIA COORDINATOR | OUT TO CUSTOMER | Stopped | |
| 10/30/2013 | IMEDINA1 | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | |
| 10/30/2013 | IMEDINA1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | |
| 10/30/2013 | IMEDINA1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | |
| 10/30/2013 | IMEDINA1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | |
| 10/30/2013 | IMEDINA1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 10/30/2013 | IMEDINA1 | UTILITY CLEARANCES | COX COMMUNICATION | Denied | |
| 10/30/2013 | IMEDINA1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 10/30/2013 | IMEDINA1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | |
| 10/30/2013 | IMEDINA1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | |
| 10/31/2013 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Approved | |
| 11/14/2013 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approv-Cond | Note: If the common area landscape irrigation system needs to cross public streets, you will need to record a 5' wide easement for those line crossings. If you can keep from crossing the road, you are approved. Let me know if you have questions. |
| 12/13/2013 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | December 12, 2013 SUBJECT: Haciendas at Wrightstown II PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval at this time. The following comments need to be addressed prior to in the subsequent review submittal. Please return redlined drawings with next submittal. 1. Include the plan number "I-2013-019" in the title block of each sheet. 2. Include Development Services Department PIA activity number "T13PI00021"on cover sheet. 3. Sheet 1: Provide recordation information for the re-plating of Haciendas at Wrightstown. 4. Sheet 1: Revise general paving notes and title block as noted on red line drawings. Title should be identical for all sheets. Specific sheet details may be placed above title block. 5. Label on plan view and provide a dimensioned detail or reference a standard detail for all for all proposed drainage structures. 6. Provide hydraulic computations for the sizing of proposed sidewalk scuppers. 7. Provide curb access ramps as indicated on redline drawings to provide ADA access at end of proposed sidewalk. 8. If proposed curb depression at Sta. +/- 3+11, RT is intended for vehicle access, a driveway apron Per PC/COT Std. 206 will need to be provided with removable post barricades Per PC/COT Std. 107. 9. Is an easement for the proposed irrigation crossing at Sta. +/- 2+25 being recorded on the final plat? If not, a separate easement will have to be recorded for it and recordation information noted on the paving plans. 10. Address comments on redline plan set. Responses can be noted on redline drawings. Please Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |
| 12/13/2013 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | We have reviewed this plan and have the following comments: 1. Please provide a Streets and Traffic Maintenance signature line on the cover sheet. 2. Sheet 2 - There appears to be a drainage to the south of lot 16. Is this common area maintained by the HOA? 3. Sheet 2 - Ohana Place - Are the dpressed curb areas through the sidewalks new scuppers? Also, is there rip rap behind them? No further comments. Lance Peterson, P.E. Streets and Traffic Maintenance 520-837-6777 |