Plan Review Detail
Review Status: Completed
Review Details: PIA - RESUBMITTAL
Plan Number - T13PI00013
Review Name: PIA - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/19/2014 | LINZUNZA | UTILITY CLEARANCES | COT STREETS DIVISION | Completed | |
| 09/19/2014 | LINZUNZA | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Completed | |
| 09/19/2014 | LINZUNZA | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | |
| 09/19/2014 | LINZUNZA | UTILITY CLEARANCES | QUEST COMMUNICATION | Completed | |
| 09/19/2014 | LINZUNZA | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Completed | |
| 09/19/2014 | LINZUNZA | UTILITY CLEARANCES | COX COMMUNICATION | Completed | |
| 09/19/2014 | LINZUNZA | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Completed | |
| 09/19/2014 | LINZUNZA | UTILITY CLEARANCES | EL PASO NATURAL GAS | Completed | |
| 09/19/2014 | LINZUNZA | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Completed | |
| 09/23/2014 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approved | |
| 10/13/2014 | ESTEVAN TINEO | DOT ENGINEERING | REVIEW | Denied | T13PI00013 Granada Ave / Cushing Street Box Culvert Rio Nuevo Multipurpose Facilities District 1. Sheet 2 of 14: Notes 17 through 23 are grading notes which are not applicable to these right-of-way (public Drainage Easement in this case) improvements, please remove these notes. 2. Please include the Typical PIA notes to these plans. 3. The plan should note that any grading outside of the easement may require a grading permit. 4. Sheet 3 of 14: Provide recordation information for Public Drainage Easement. 5. Please note that existing light poles and bases must not be within the Drainage Easement. 6. Sheet 3 of 14: Note 20: Detail is for connecting to a stormdrain pipe, not box culvert. Detail how manhole structure will be connected to box culvert structure. 7. Sheet 6 of 14: Catch Basin along Federal Bkg. Will improvements require entering Federal property to construct and to maintain? 8. Drainage Design Comments: a. Are the flows entering the proposed catch basin along the Federal building coincident with the flows from the TCC Wash. In other words, due these flows have differing times of concentration? b. If the flows arriving at the "Catch basin Along Federal Blg" have differing times of concentration as compared to the TCC flows, then can the parallel storm drain be eliminated? |
| 10/17/2014 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Approved | October 17, 2014 PROJECT NAME: Granada Ave/Cushing Street Box Culvert PLAN #: D-2013-001 ACTIVITY NUMBER: T13PI00013 PROJECT REVIEWER: Simon Ramos, EIT, Traffic Engineering, City of Tucson DOT The Signing and Striping Section has completed the reviewed of the PIA plan and recommends approval at this time. The following comments need to be addressed in the subsequent plan submittal. Please return redlined drawings with next submittal and reference PIA activity number on all correspondences. If you have any questions, I can be reached at 837-6678 or Simon.Ramos@tucsonaz.gov |
| 11/12/2014 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approved | |
| 11/13/2014 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
| 11/13/2014 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed |