Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T13OT00796
Parcel: 136412290

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T13OT00796
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/08/2013 JASON GREEN ENGINEERING REVIEW Approved July 8, 2013
FLOODPLAIN USE PERMIT NO.: T13OT00796
ADDRESS: 3301 S Marissa Dr Tucson, Arizona 85730
PROPERTY OWNER: Joaquim Delgado
3301 S Marissa Dr Tucson, Arizona 85730

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the Old Spanish Trail Wash delineation, specifically described as:

A portion of Parcel 136-41-2290, Ridgeland Park Lot 35

For the purpose of constructing a 180 LF x 6-foot high block wall with vents every 5-foot off center or at specific existing discharge points as shown on the site plan.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 8 conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the wall, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction of the wall within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. Per the Drainage way Improvement plans prepared for the subdivision the Q100 is contained within the channel (See X-Section D-2, u/s of Lot). The Q100 calculated by the engineer of record is 1429 cfs and the channel provides an 8-inch freeboard as calculated.
3) All work shall conform to the approved site plan sheets for the construction of the wall, which are made part of this permit. Specifically the wall is required to be vented every 5-feet off center to allow acceptance and discharge of onsite and offsite flows as to not adversely impact the adjacent properties.
4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T13OT00796 FOR INFORMATION PLEASE CALL 791-5550."
5) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
7) See the associated activity T13BU00814
8) This permit is specific to the improvements for 3301 S Marissa Dr as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Joaquim Delgado
ADDRESS: 3301 S Marissa Rd Tucson, Arizona 85730
PHONE: 520-576-7591
OWNER: Joaquim Delgado
ADDRESS: 3301 S Marissa Rd Tucson, Arizona 85730
PHONE: 520-576-7561

(EXPIRATION DATE) Month: _07 Day: 08 Year: 2014

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/08/2013 FERNE RODRIGUEZ OUT TO CUSTOMER Completed