Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T13CM07544
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/22/2014 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 1-22-14 Activity: T13CM07544 Address: 2921 E La Madera Dr Applicant: David Mlazovsky This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Correct references to sheet 'A-12' on sheet A-4. 2. Correct mislabeled page references for ridge vent detail on sheet A-7. SITE PLAN: 3. Clarify building distance to property line. Dimension lines do not line up with building perimeter. STRUCTURAL / FRAMING PLAN: 4. Clarify header materials. Section detail on page A-7 shows a box beam design and notes indicate solid sawn lumber. PLUMBING PLAN: 5. Provide a gas appliance schedule for all appliances served by the gas meter and specify the total developed length of gas piping from the meter to the most remote appliance on the system, G2413.1, Table G2413.4 (1). 6. Provide a water fixture unit schedule for all plumbing fixtures supplied by the water meter (including existing) P2903.6. 7. Specify the maximum developed length of water line from the meter the furthest appliance served, and the lowest available working pressure, P2903.7. ELECTRICAL PLAN: 8. Include sub-panel on riser diagram with feeder conductors, conduit sizes, and over-current protection (with appropriate correction factors), E3705.5. 9. Provide equipment cut sheet for proposed ceiling fans located under open framed trellis to verify listing for weather exposure. OUTDOOR LIGHTING CODE 10. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Model plans should specify a minimum lot size for the proposed exterior lighting. 11. Flood light not permitted in proposed location on alley side of garage. Exterior luminaires shall be full cutoff within 25 feet of adjacent property lines, 401.3.3. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
| 12/23/2013 | DAVID RIVERA | ZONING | REVIEW | Denied | PDSD Zoning Review From: David Rivera Date: 12/23/13 SFR Addition DDO approval required prior to zoning approval. DDO is in process as of this review. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/04/2014 | SHANAE POWELL | OUT TO CUSTOMER | Completed |
| 02/04/2014 | CPIERCE1 | REJECT SHELF | Completed |