Permit Number: T13CM07311
Parcel: 129020510

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T13CM07311
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/17/2014 SPOWELL1 WWM REVIEW Needs Review
12/13/2013 ROBERT SHERRY WATER REVIEW Approved
12/13/2013 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
12/13/2013 MARTIN BROWN FIRE REVIEW Approved
12/13/2013 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
12/13/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Provide separate indirect waste pipes for each compartment of the 3-compartment sink to protect against cross-contamination or fouling. Reference: Sections 801.2 and 802.1.8, IPC 2012.
2. Verify that the lack of a grease interceptor is acceptable to the Regional Wastewater reclamation department of Pima County (contact: Rusty Riccaboni 724-6200).
3. Provide information for the operation of the batch freezer (K8) with regard to its water use. Reference: section 929, IMC 2012, as amended by the City of Tucson.