Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T13CM07159
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/04/2014 | MARTIN BROWN | FIRE | REVIEW | Reqs Change | A RESIDENCE BUILT UNDER THE INTERNATIONAL BUILDING CODE REQUIRES FIRE SPRINKLERS EITHER CHANGE COVER SHEET TO INDICATE INTERNATION RESIDENTIAL CODE OR ADD NOTE INDICATING FIRE SPRINKLERS WILL BE INSTALLED. |
11/19/2014 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 11-120-14 Activity: T14CM07159 Address: 356 W 18th St Applicant: Scott Neeley This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Clarify references to sheet A-9 as indicated on sheets A-4 and S-1. 2. The City of Tucson has adopted the 2012 International family of codes. Correct references to the 2006 IRC on sheet P-1 or appeal must be made to the Building Official for alternate code use. FLOOR PLAN: 3. Doors between a garage and a residence shall be self-closing, R302.5.1. SECTIONS - DETAILS: 4. Provide continuous framing behind gypsum intersections or provide continuous gypsum from foundation to roof sheathing for fire rated wall assemblies, R302.1 as amended. PLUMBING PLAN: 5. Cleanouts are required at the kitchen sink area, State amendment. ELECTRICAL PLAN: 7. Specify minimum 6' separation of roof-top receptacles from the spa, E4203.1.1. 8. Indicate GFCI protection of receptacle at garage ceiling, E3902. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Clayton.Trevillyan@tucsonaz.gov Residential Plan Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
11/24/2014 | AROMERO4 | OUT TO CUSTOMER | Completed |