Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T13CM06692
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/11/2013 | RAFAEL CANCINO | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: December 11, 2013 Activity: T13CM06692 Address: 2308 W. Ocelot Dr. Applicant: Mr. Martin Mendoza Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide revised plans and calculations, highlighting any changes or with a written response to each of the notated items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2012 IRC with amendments on 1/1/2012. Show the code references on the plans. GENERAL NOTES: " Limit all code references to those recognized by the City of Tucson. Adopted 2012 codes are listed at the Planning & Development Services web site. Show the code references used for the design. DETAIL PLAN: 1. Provide 4-#4 vertical rebars (one per cell) in vertical CMU columns. 2. Provide continuous strapping of ramada's middle beams. 3. Provide 1/2" sheathing on built-up roof or 3/8" sheathing with clips, R503.2. 4. Detail 3, splicing of beams are not allowed. Ensure connection is placed over structural column. 5. Porch roof extension sheathing does not require clipping, since rafters are spaced at 16" o/c. 6. Ensure new porch rafters are connected existing trusses and that rafters rest on top of existing house exterior load-bearing wall. ELECTRICAL PLAN: 1. Ensure a minimum of 7' vertical clearance under any portion of ceiling fans, including light fixture attachment. 2. Provide 3-way fan/light switches. If you have any questions please contact: Rafael Cancino (520) 909-4891 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/13/2013 | SHANAE POWELL | OUT TO CUSTOMER | Completed |
| 12/13/2013 | CPIERCE1 | REJECT SHELF | Completed |